Infiniium Ordering Information
8000 Series oscilloscopes
DSO8064A MSO8064A DSO8104A MSO8104A
Bandwidth 600 MHz 600 MHz 1 GHz 1 GHz
Input channels 4 analog 4 analog +
16 logic
4 analog 4 analog +
16 logic
Maximum sample
rate (2 channel)
4 GSa/s 4 GSa/s 4 GSa/s 4 GSa/s
Standard memory
(2 channel)
8 Mpts 8 Mpts 8 Mpts 8 Mpts
The above models include: optical USB mouse, condensed keyboard, User’s Quick Start Guide in English language (other
languages also available), accessory pouch, front panel cover, power cord, 10073C 10:1 passive probe (qty 4) and with
MSO version 54826-68701 logic cable kit.
Recommended probes
Model Description
1156A 1.5 GHz active probe
1130A 1.5 GHz InfiniiMax probe amplifier – No probe heads included
1
1. For a complete probing solution, also order a connectivity kit or individual probe head(s) (E2675A, E2668A, E2669A).
For more information on selecting the right probe see page 19.
Memory options
Option number – Factory installed Option number – User installed
Description
080 N5407A-080 16 Mpts on 2 channels, 8 Mpts on 4 channels
160 N5407A-160 32 Mpts on 2 channels, 16 Mpts on 4 channels
320 N5407A-320 64 Mpts on 2 channels, 32 Mpts on 4 channels
640 N5407A-640 128 Mpts on 2 channels, 64 Mpts on 4 channels
Memory can be added both at the time of initial purchase and after with a user installed option.
For a comprehensive list and selection criteria, refer to the Oscilloscopes Probes and Accessories Selection Guide (Agilent