Programming instructions

14
RTCA/DO-160 for Airborne Equipment
To test airborne equipment according to the RTCA/DO-160 specification, select
RTCA/DO-160 in the Tests menu. Only single-phase equipment is supported,
three-phase equipment is not supported.
To configure the Test Pass/Fail criteria of the RTCA/DO-160 tests, click
Options. You can specify either ac input or dc input tests. Note that both
Pass/Fail criteria must be true for the ac or dc input tests to pass.
Click
Select the
Pass/Fail criteria
for the test items.
Check the test
items to include in
the test
Click here to start
the test.
When baes on input power, the
ac source measures the input
power of the DUT at the
beginning and end of each test
Sends completed
test results to the
default printer.
Test passes if the difference in
input power at the start of test
and at end of the test is <= to the
% of power difference specified.
Test also passes if the input
power is >= to the minimum
power specified in Watts.
Indicates which
item is presently
being tested.
Indicates the
total estimated
time of test.
Select the test
category
(A, B, E, or Z)
Select ac or dc
input power.