TEST_03. TX Output Power
TEST_03. TX Output Power 
This test measures the power available at the output terminals of the transmitter 
when connected to a 50 
Ω load. 
Testing is performed at the nominal supply voltage and can also be performed 
with high and low supply voltages for extreme measurements if a programmable 
power supply is configured to the test set. Refer to 
chapter 1, "Product 
Description," on page 15
 for a list of programmable power supplies. 
Pass/Fail Limits Used
 Pass/Fail Limit 33, TX Output Power 
 Pass/Fail Limit 34, TX Output Power at High Supply 
1
 Pass/Fail Limit 35, TX Output Power at High Supply Low SW 
1
 Pass/Fail Limit 36, Output Power at Low Supply 
1
 Pass/Fail Limit 37, TX Output Power at Low Supply Low SW 
1
 Pass/Fail Limit 38, TX Output Power at Low Switch Setting 
2
Test Parameters Used
 Parameter 3, RT High Supply Voltage 
1
 Parameter 4, RT Low Supply Voltage 
1
 Parameter 5, RT Nominal Supply Voltage 
 Parameter 31, TX Output Power @Low Switch 
2
1. These pass/fail limits and test parameters are used only when an external power 
supply is configured to the test set.
2. This specification and the test parameter is used only if the power supply has a low 
switch setting.