Technical data
176 S:\hp11807a\OPT001\USRGUIDE\BOOK\chapters\descrptn.fb
Chapter 4, Test, Parameter, and Pass/Fail Limit Descriptions
Pass/Fail Limit 32, TX Modulation Limiting
Pass/Fail Limit 32, TX Modulation Limiting
This sets the pass/fail limits for testing a transmitter’s modulation limiting.
Pass/Fail limits are determined from an applicable radio specification or industry
standard, such as:
• Radio specification: Modulation Deviation
• Industry standard: EIA/TIA-603, Section 2.2.3, Modulation Limiting
For Example:
If your industry standard defines the maximum modulation limiting to be not
more than the full-rated system deviation (for example, 5 kHz), enter
0 in the
lower-limit column and
5 in the upper-limit column. Limits are entered in kHz.
It’s Used in the Following Tests:
TEST_04. TX Modulation Limiting
TEST_21. TX Quick Test