Technical data

164 S:\hp11807a\OPT001\USRGUIDE\BOOK\chapters\descrptn.fb
Chapter 4, Test, Parameter, and Pass/Fail Limit Descriptions
Pass/Fail Limit 20, TX Audio Response Delta From 6 dB/oct
Pass/Fail Limit 20, TX Audio Response Delta From 6 dB/oct
This sets the pass/fail limits for testing a transmitter’s audio-frequency-response
variation from a true 6 dB/octave pre-emphasis slope.
Pass/Fail limits are determined from an applicable radio specification or industry
standard, such as:
Radio standard: Audio Response
Industry standard: EIA/TIA-603, Section 2.2.6, Audio Frequency Response
For Example:
If your radio specification defines audio response to be within +1 and
3 dB of
6 dB/octave pre-emphasis characteristic and you want to test both limits on the
radio, enter
3 in the lower-limit column and 1 in the upper-limit column. Limits
are entered in dB.
It’s Used in the Following Tests:
TEST_05. TX Audio Frequency Response
TEST_21. TX Quick Test