Technical data
146 S:\hp11807a\OPT001\USRGUIDE\BOOK\chapters\descrptn.fb
Chapter 4, Test, Parameter, and Pass/Fail Limit Descriptions
Pass/Fail Limit 2, RX Audio Distortion
Pass/Fail Limit 2, RX Audio Distortion
This defines pass/fail limit values for testing a receiver’s audio distortion when
the radio’s volume is set to the standard input-signal level.
Pass/Fail limits are determined from an applicable radio specification or industry
standard, such as:
• Radio specification: Audio Distortion
• Industry standard: EIA/TIA-603, Section 2.1.12, Audio Distortion.
For Example:
If your industry standard defines the maximum harmonic distortion as 10% at the
rated output power and you want to test the radio’s upper limits only, enter
0 in
the lower-limit column and
10 in the upper-limit column. Limits are entered in %.
It’s Used in the Following Tests:
TEST_12. RX Audio Distortion
TEST_20. RX Quick Test