Chapter 4, Test, Parameter, and Pass/Fail Limit Descriptions
Parameter 17, RX Tolerance for Setting Volume
Parameter 17, RX Tolerance for Setting Volume
This test parameter sets a tolerance window for the maximum percentage of error
allowed on the meter screen. The meter screen is displayed on the test set during
testing for manually setting the radio’s volume. The tolerance for setting volume
should be as accurate as the radio’s volume control will allow.
For Example:
If maximum audio power is 10 watts (set up in
Parameter 11, RX Maximum Audio
Power
) the meter screen on the test set will display a full-scale reading of 15 Watts
since the software scales the meter screen by 50%. The tolerance window
displayed on the meter screen will be a percentage of the 10 Watts. In this
example, test
Parameter 17, RX Tolerance for Setting Volume set to “10%” would
create a tolerance window of 1 Watt, “5%” would create a tolerance window of
0.5 Watts, and so forth.
The value should be based on the highest accuracy the radio volume control
allows. Enter a number equal to the accuracy you want and then run a test to see if
the radio’s volume control allows you to make the setting. If you cannot adjust the
volume within the tolerance window, enter a larger number. The value is entered
in % error.
It’s Used in the Following Tests:
TEST_11. RX Hum and Noise
TEST_12. RX Audio Distortion
TEST_13. RX Audio Frequency Response
TEST_14. RX Usable Sensitivity
TEST_15. RX Audio Squelch Sensitivity
TEST_16. RX Squelch Blocking
TEST_17. RX CTCSS/CDCSS Opening
TEST_19. RX Variation of Sens with Freq
TEST_20. RX Quick Test