Technical data
128 S:\hp11807a\OPT001\USRGUIDE\BOOK\chapters\descrptn.fb
Chapter 4, Test, Parameter, and Pass/Fail Limit Descriptions
Parameter 16, RX Standard RF Input Level
Parameter 16, RX Standard RF Input Level
This test parameter sets the standard RF input level (which is the test set’s RF
generator’s output level) that is used in receiver testing.
For Example:
The EIA standard specifies the standard input-signal level as 60 dB above the
reference (usable) sensitivity. The reference sensitivity is specified for each RF
band.
If your radio was specified for 1 µV sensitivity, then the input level should be 60
dB above that or 1000 µV. In this case, enter
1000 in the value column. The value
is entered in µV.
It’s Used in the Following Tests:
TEST_11. RX Hum and Noise
TEST_12. RX Audio Distortion
TEST_13. RX Audio Frequency Response
TEST_14. RX Usable Sensitivity
TEST_15. RX Audio Squelch Sensitivity
TEST_16. RX Squelch Blocking
TEST_17. RX CTCSS/CDCSS Opening
TEST_18. RX Audio Sensitivity
TEST_19. RX Variation of Sens with Freq
TEST_20. RX Quick Test