Technical data
114 S:\hp11807a\OPT001\USRGUIDE\BOOK\chapters\descrptn.fb
Chapter 4, Test, Parameter, and Pass/Fail Limit Descriptions
Parameter 2, RT Full Rated System Deviation
Parameter 2, RT Full Rated System Deviation
This test parameter sets the full-rated (maximum) deviation used by the test set
during receiver and transmitter tests.
Besides being used in the tests shown below, full-rated system deviation is set on
the test set by subroutines in the software whenever:
❒ the test set is set to the standard receiver mode.
❒ transmitter deviation is set on the test set.
For Example:
If your industry standard specifies the full-rated system deviation to be 5 kHz,
enter
5 in the value column. The value is entered in kHz.
It’s Used in the Following Tests:
TEST_04. TX Modulation Limiting
TEST_05. TX Audio Frequency Response
TEST_06. TX Audio Distortion
TEST_07. TX Microphone Sensitivity
TEST_08. TX FM Hum and Noise
TEST_11. RX Hum and Noise
TEST_13. RX Audio Frequency Response
TEST_16. RX Squelch Blocking
TEST_18. RX Audio Sensitivity