Technical data
103
S:\hp11807a\OPT001\USRGUIDE\BOOK\chapters\descrptn.fb
Chapter 4, Test, Parameter, and Pass/Fail Limit Descriptions
TEST_13. RX Audio Frequency Response
TEST_13. RX Audio Frequency Response
This test compares the audio frequency response of your transmitter to a 6 dB/
octave pre-emphasis curve from 0.5 kHz to 2.5 kHz. Variation from that pre-
emphasis curve is measured separately from frequencies <0.5 kHz and >2.5 kHz.
Audio connections from the radio to the test set are required for this test.
Receiver audio-frequency response is measured in “dB error” from a 6 dB/octave
curve.
Pass/Fail Limits Used
Pass/Fail Limit 3, RX Audio Freq Resp Delta from 6 dB/Oct
Pass/Fail Limit 4, RX Audio Frequency Response Roll <0.5 kHz
Pass/Fail Limit 5, TX Audio Frequency Response Roll >2.5 kHz
Test Parameters Used
Parameter 2, RT Full Rated System Deviation
Parameter 6, RX Audio Freq Response Step Frequency
Parameter 11, RX Maximum Audio Power
Parameter 16, RX Standard RF Input Level
Parameter 17, RX Tolerance for Setting Volume
Testing conditions Fixed by the Software
• Receiver volume is set to 50% of maximum when the deviation is set to 60% of rated
system deviation.
• Deviation is the reduced to 20% of rated system deviation and a reference level is read
at a 1 kHz rate.
• The audio frequency is then swept from 300 Hz to 3 kHz (in steps determined by test
6) and the audio frequency response is measured.