Specifications

This 2000 W DC power supply
provides over 2000 watts at either
70 or 80 volts. This makes it par-
ticularly suitable for a variety of
test scenarios for 48 volt systems.
Telephone network equipment is
one example of such a 48 volt bus
application. It also has the unusual
combination of high efficiency and
low noise operation.
Programming of the DC output and
the extensive protection features
can be done either from the front
panel or using industry standard
SCPIcommands,viatheGPIB.
Using the serial link, up to 16 power
supplies can be connected through
oneGPIBaddress.Testsystem
integration can be further simplified
by using the VXIPlug&Play drivers.
The output voltage and current can
also be controlled with analog signals.
This is helpful for certain types of
noisy environments, and also imme-
diate reactions to process changes.
Lab-bench use is enhanced by the
fan-speed control, which minimizes
acoustic noise. The extremely low
ripple and noise helps the built-in
measurement system make extremely
accurate current and voltage mea-
surements.
High Performance DC Power Supplies speed and accuracy for test optimization
Specifications
(at to 55°C unless
otherwise specified)
E4356A
More detailed specifications at
www.agilent.com/find/E4356
84
Dual range output
Fast, low-noise outputs
Analog control of output voltage and current
Fan-speed control to minimize acoustic noise
Built-in measurements and advanced programmable features
Protection features to ensure DUT safety
E4356A
Single-Output
2000 W GPIB
Number of outputs 1
GPIB
Yes
Output ratings
Voltage 0 to 70 V/0 to 80 V
Current 0 to 30 A/0 to 26 A
Programming accuracy
at 25
°
C ±5
°
C
(% of setting plus fixed)
Voltage 0.04% + 80 mV
+Current 0.1% + 25 mA
Ripple and noise
20 Hz to 20 MHz
Voltage rms 2 mV
peak-peak 16 mV
Current rms 25 mA
DC measurement accuracy
(via GPIB or front panel meters
with respect to actual output
at 25°C ±5°C
Voltage 0.05% + 120 mV
Current 0.1% + 35 mA
Transient response time
Time for the output voltage to <900 s
recover to within 20 mV or 0.1%
of the voltage rating of the unit
following a change in load current
of up to 50% of the output
current rating.
Application notes
Agilent DC Power Supplies
for Base Station Testing
5988-2386EN
10 Practical Tips You Need to
Know About Your Power Products
5965-8239E
10 Hints for Using Your Power Supply
to Decrease Test Time
5968-6359E
Supplemental characteristics
for all model numbers
DC floating voltage: Output terminals can
be floated up to ±240 VDC maximum from
chassis ground.
Remote sensing: Up to half the rated
output voltage can be dropped in each
load lead. The drop in the load leads
subtracts from the voltage available for
the load.