Specifications

Specifications
(at to 55°C unless
otherwise specified)
N6976A N6977A N7976A N7977A
Supplemental Characteristics (Non-warranted characteristics determined by design
that are useful in applying the product)
Over-voltage protection
Maximum setting 144 V 192 V 144 V 192 V
Accuracy 0.03% + 17 mV 24 mV 11 mV 14 mV
Response time
3
<30 µs <30 µs <30 µs <30 µs
Measurement noise (peak)
Voltage 18 mV 23 mV 18 mV 23 mV
Current 6 mA 4 mA 6 mA 4 mA
Current (low range) N/A N/A 4 mA 2 mA
Output current noise
CC rms 15 mA 15 mA 15 mA 15 mA
Common mode current
CC rms 2 mA 2 mA 2 mA 2 mA
CC peak to peak 10 mA 10 mA 10 mA 10 mA
Volt up-programming time
4
10% to 90% 3 ms 3 ms 0.5 ms 0.5 ms
Settling time
6
10 ms 10 ms 1 ms 1 ms
Volt down-programming time
5
90% to 10% 3 ms 3 ms 0.35 ms 0.35 ms
Settling time
6
10 ms 10 ms 0.8 ms 0.8 ms
Current up-programming time
7
10% to 90% 2.5 ms 2.5 ms 2.5 ms 2.5 ms
Output-on delay time
Voltage priority 12 ms 12 ms 12 ms 12 ms
Voltage priority (with relay on) N/A N/A 38 ms 38 ms
Current priority 14 ms 14 ms 14 ms 14 ms
Current priority (with relay on) N/A N/A 46 ms 46 ms
Line regulation
8
Voltage <10 µV <10 µV <10 µV <10 µV
Current <10 µA <10 µA <10 µA <10 µA
Small signal bandwidth N7976A & N7977A
Voltage programming
9
N/A N/A DC to 1 kHz (-1dB); DC to 2 kHz (-3dB)
Current programming
10
N/A N/A
DC to 70 Hz (-1dB); DC to 120 Hz (-3dB)
Voltage measurement N/A N/A
DC to 14 kHz (-1dB); DC to 25 kHz (-3dB)
Current measurement N/A N/A
DC to 14 kHz (-1dB); DC to 25 kHz (-3dB)
77
APS General Information
APS N6900 Series and N7900 Series
power supply power requirements
Connect the power cord that was
supplied with your unit to the AC
mains connector on the rear of
the unit. Note that these cords are
standard and are specially rated to
handle the power needs of the APS
supply they are shipped with. The
AC input on the back of your unit
is a universal AC input. It accepts
nominal line voltages in the range of
100 VAC to 240 VAC. The frequency
can be 50 Hz, 60 Hz, or 400 Hz. AC
mains rated below 180 VAC cannot
supply enough current to power
either the 1 kW or the 2 kW N6900
and N7900 models to their full rated
output power. In such cases, when
a 1 kW or 2 kW APS power supply
is connected to below 180 VAC AC
mains, the power supply will still
operate normally, but its maximum
output power will be limited to 700 W.
In this condition, if the power supply
exceeds 700 W of output power the
instrument turns off the output and
sets the CP+ status bit.
APS power supply connectivity
All APS power supplies come
standardwithGPIB(IEEE-488),
LAN(LXICore),andUSBremote
programminginterfaces.GPIBand
LAN parameters can be set via the
frontpanel.TheAPSisLXICore
2011 compliant and includes a
built-in Web interface. This means
you can control the APS remotely
using a Web browser and a LAN
connection.
Single Output: 1 & 2 KW GPIB, LAN (LXI Core), USB
(Continued)
More detailed specifications at
www.agilent.com/find/N6900
www.agilent.com/find/N7900
Advanced Power System DC power supplies overcome the toughest power test challenges
Notes:
3
From occurrence of over-voltage to start of shutdown
4
With full resistive load and a voltage transition from 0.1% to 100% of rated output
5
With no load and a voltage transition from 100% to 0.1% of rated output
6
From start of voltage change to within 0.1% of final full scale value
7
With full resistive load and a current transition from 0.1% to 100% of rated output
8
Line regulation is guaranteed by design
9
With High Bandwidth setting, resistive load condition
10
With resistive load condition