Specifications
Specifications
(at 0° to 55°C unless
otherwise specified)
N6976A N6977A N7976A N7977A
Supplemental Characteristics (Non-warranted characteristics determined by design
that are useful in applying the product)
Programming range
Voltage 0.12 to 122.4 V 0.16 to 163.2 V 0.12 to 122.4 V 0.16 to 163.2 V
Current (no dissipator) -1.7 to 17 A -1.275 to 12.75 A -1.7 to 17 A -1.275 to 12.75 A
Current (with dissipator) -17 to 17 A -12.75 to 12.75 A -17 to 17 A -12.75 to 12.75 A
Programming resolution
Voltage 16.9 mV 22.5 mV 2.5 mV 3.6 mV
Current 5 mA 3.8 mA 0.32 mA 0.24 mA
Current measurement range
High range -37.6 to 37.6 A -28.1 to 28.1 A -37.6 to 37.6 A -28.1 to 28.1 A
Low range N/A N/A -1.84 to 1.84 A -1.37 to 1.37 A
Resistance programming
Range 0 to 6.8 Ω 0 to 12.8 Ω 0 to 6.8 Ω 0 to 12.8 Ω
Accuracy
1
0.1% + 0.1% + 0.06% + 0.06% +
17.7 mΩ*A 25.6 mΩ*A 17.7 mΩ*A 25.6 mΩ*A
Resolution 60 µΩ 108 µΩ 60 µΩ 108 µΩ
Temperature coefficient 0.0060% 0.0060% 0.0050% 0.0046%
Programming & measurement temperature coefficient
Voltage
2
0.0022% + 430 µV 570 µV 430 µV 530 µV
Current
2
0.0065% + 12 µA 0.0058% + 30 µA 0.0036% + 40 µA 0.0036% + 30 µA
Current measurement low range temperature coefficient
2
N/A N/A 0.0046% + 12 µA 0.0045% + 9 µA
76
N7906A power assistant software
The APS N7906A power assistant
software is a free application
that works with the APS power
supplies. The power assistant
software provides three main
capabilities for working with the
APS power supplies:
•ControlanAPSpowersupply
using the Power assistant soft-
ware’s intuitive graphical user
interface
•Retrieveandviewdatafrom
the optional APS power supply
black box recorder
(see Figure 9)
•Performtriggerroutingand
configure logical trigger
expressions (see Figure 10)
The power assistant software is
available for download at:
www.agilent.com/find/powerassistant.
For more information on the
APS power assistant software,
refer to the APS user manual at:
www.agilent.com/find/APS-doc.
Single Output: 1 & 2 KW GPIB, LAN (LXI Core), USB
(Continued)
More detailed specifications at
www.agilent.com/find/N6900
www.agilent.com/find/N7900
Advanced Power System DC power supplies overcome the toughest power test challenges
Notes:
1
Resistance programming accuracy varies with output current. For example, for an N7970A unit at 0.1 Ω with
a 50 A transient, accuracy is: (0.1 Ω*0.06%) + (1.6 mΩ*A/50 A) = 92 µΩ.