Specifications
66
• Accurately measure power
storage and efficiency: In addition
to high-accuracy voltage and
current measurement capabilities,
APS power supplies offer built-in
power, peak power, amp-hour,
and watt-hour calculations. These
measurements help simplify your
power efficiency and storage
calculations.
• Additional measurement
capabilities:
• Adjustable measurement
intervals for both average and
digitized measurements
• External logging capability,
which simplifies data logging
in ATE software
• Pre-, post-, and level triggering
for pinpointing exactly where
and when to measure
• Accurately capture dynamic cur-
rent profiles: APS has two current
measurement ranges that allow it
to measure micro-amps to amps.
The APS uses seamless ranging
technology to transition from one
measurement range to the other
without discontinuities in the out-
put power or in measurement data.
(See figure 1)
Single Output: 1 & 2 KW GPIB, LAN (LXI Core), USB
(Continued)
Specifications
(at 0° to 55°C unless
otherwise specified)
More detailed specifications at
www.agilent.com/find/N6900
Advanced Power System DC power supplies overcome the toughest power test challenges
N6970A N6971A N6972A N6973A N6974A
Number of outputs 1 1 1 1 1
GPIB, LAN, USB Yes Yes Yes Yes Yes
DC ratings
Voltage 0 to 9 V 0 to 20 V 0 to 40 V 0 to 60 V 0 to 80 V
Current 0 to 200 A 0 to 100 A 0 to 50 A 0 to 33.3 A 0 to 25 A
Current sink 10% rating -20 A -10 A -5 A -3.33 A -2.5 A
Current sink 100% rating
1
-200 A -100 A -50 A -33.3 A -25 A
Power
2
1800 W 2000 W 2000 W 2000 W 2000 W
Output ripple and noise
3
CV rms 1 mV 1 mV 1 mV 1 mV 1 mV
CV peak to peak 9 mV 9 mV 9 mV 9 mV 9 mV
Load regulation
Voltage 0.5 mV 0.75 mV 1.5 mV 2 mV 2 mV
Current 15 mA 6 mA 1.5 mA 1.5 mA 1.5 mA
Voltage programming & measurement accuracy
4,5,6
Lead drop ≤1 V max 0.03% + 1.5 mV 3 mV 6 mV 9 mV 12 mV
Lead drop ≤25% of V rating
0.03% + 1.9 mV 4 mV 7.9 mV 12 mV 16 mV
Current programming & measurement accuracy
4
0.1% + 60 mA 30 mA 15 mA 10 mA 8 mA
Transient response
7
Recovery time 100 µs 100 µs 100 µs 100 µs 100 µs
Settling band 150 mV 150 mV 100 mV 150 mV 200 mV
Notes:
1
Current sinking up to 100% of rated current requires one power dissipator for 1 kW models, and two power
dissipators for 2 kW models. 2 kW models with one power dissipator can sink 50% of their rated current.
2
Maximum continuous power available is derated at 1% of rating per degree C from 40°C to 55°C
3
From 20 Hz to 20 MHz
4
At 23°C ±5°C after a 30 minute warm-up; measurement NPLC=1; valid for 1 year
5
With resistance programming enabled, the voltage programming offset component increases by a factor of 2.1
6
Load lead drop applies to each load lead
7
Time to recover to within the settling band following a load change from 50% to 100% of full load (10 µs rise time)