Specifications

Overcome your power test
challenges with the Advanced
Power System family
With Advanced Power System (APS)
1 kW and 2 kW system power sup-
plies, you get a new level of power
supply performance. The Advanced
Power System (APS) family was
designed with VersaPower archi-
tecture to help you overcome your
toughest power test challenges by
delivering industry-leading specifi-
cations and innovative features in
an integrated solution for today’s
advanced ATE power testing needs.
VersaPower architecture delivers
the fastest, most accurate, integrated
power system
Accelerate test-system throughput
with industry-leading speed
Capture your DUT’s current profile
with accurate measurements
Reduce your ATE development
time and cost with highly integrated
capabilities
Agilent N6900 Series DC power supplies
Designed for ATE applications
where high performance is critical
Agilent N7900 Series dynamic DC
power supplies
Designed for ATE applications
where high-speed dynamic sourcing
and measurement is needed
Advanced Power System DC power supplies overcome the toughest power test challenges
Specifications
(at to 55°C unless
otherwise specified)
Accelerate test throughput with industry-leading command processing time
Accurately characterize your DUT's power profile with advanced measurements
Continuously source and sink current for power storage and test applications
Smart triggering: Increased throughput, DUT protection, and reduced complexity
Track power events with a black box recorder
Small high density 3U package
Built-in paralleling capability up to 10 kW
Single-Output
1 & 2 KW GPIB, LAN (LXI core), USB
N6950A N6951A N6952A N6953A N6954A
Number of outputs
1 1 1 1 1
GPIB, LAN, USB
Yes Yes Yes Yes Yes
DC ratings
Voltage 0 to 9 V 0 to 20 V 0 to 40 V 0 to 60 V 0 to 80 V
Current 0 to 100 A 0 to 50 A 0 to 25 A 0 to 16.7 A 0 to 12.5 A
Current sink 10% rating
-10 A -5 A -2.5 A -1.67 A -1.25 A
Current sink 100% rating
1
-100 A -50 A -25A -16.7 A -12.5 A
Power
2
900 W 1000 W 1000 W 1000 W 1000 W
Output ripple and noise
3
CV rms 1 mV 1 mV 1 mV 1 mV 1 mV
CV peak to peak 9 mV 9 mV 9 mV 9 mV 9 mV
Load regulation
Voltage 0.5 mV 0.75 mV 1.5 mV 2 mV 2 mV
Current 8 mA 3 mA 1 mA 1 mA 0.8 mA
Voltage programming & measurement accuracy
4, 5, 6
Lead drop ≤1 V max 0.03% + 1.5 mV 3 mV 6 mV 9 mV 12 mV
Lead drop ≤25% of V rating
0.03% + 1.9 mV 4 mV 7.9 mV 12 mV 16 mV
Current programming & measurement accuracy
4
0.1% + 30 mA 15 mA 8 mA 5 mA 4 mA
Transient response
7
Recovery time 100 µs 100 µs 100 µs 100 µs 100 µs
Settling band 150 mV 150 mV 100 mV 150 mV 200 mV
N7909A, N6950A-N6954A, N6970A-N6974A
N7950A-N7954A, N7970A-N7974A, N6976A,
N6977A, N7976A, N7977A
Notes:
1
Current sinking up to 100% of rated current requires one power dissipator for 1 kW models, and two power
dissipators for 2 kW models. 2 kW models with one power dissipator can sink 50% of their rated current.
2
Maximum continuous power available is derated at 1% of rating per degree C from 40°C to 55°C
3
From 20 Hz to 20 MHz
4
At 23°C ±5°C after a 30 minute warm-up; measurement NPLC=1; valid for 1 year
5
With resistance programming enabled, the voltage programming offset component increases by a factor of 2.1
6
Load lead drop applies to each load lead
7
Time to recover to within the settling band following a load change from 50% to 100% of full load (10 µs rise time)
More detailed specifications at
www.agilent.com/find/N6900
63