Specifications

This series of linear-regulated
80-100 W DC power supplies is
designed to maximize the throughput
of DUTs through the manufacturing
testprocess.Bothprogramming
and measurement are optimized for
speed. The active downprogrammer
can sink up to the full rated current
of the power supply, which quickly
brings the power supply output to
zerovolts.The6630Bseriesoffers
many advanced programmable
features including stored states
and status reporting. Programming
is done using industry standard
SCPIcommandsviatheGPIBor
RS-232. Test system integration is
further simplified by using the
VXIPlug&Play drivers. The optional
relays simplify system design and
troubleshooting.
The optional front panel binding
postsmakethe6630Bseries
convenient on the R&D lab bench.
The built-in microamp measurement
system helps the engineer to easily
and accurately monitor the output
voltage and current without a
complicated test setup.
Application notes
10 Practical Tips You Need to
Know About Your Power Products
5965-8239E
10 Hints for Using Your Power Supply
to Decrease Test Time
5968-6359E
High Performance DC Power Supplies speed and accuracy for test optimization
Specifications
(at to 55°C unless
otherwise specified)
6631B 6632B 6633B 6634B
More detailed specifications at
www.agilent.com/find/6630
47
Fast, low-noise outputs
Programmable active down-programmer sinks the full rated current
Dual-range, precision low current measurement
Optional isolation and polarity reversal relays
Built-in measurements and advanced programmable features
Protection features to ensure DUT safety
6631B - 6634B
Single-Output
80-100 W GPIB
Number of outputs 1 1 1 1
GPIB
Yes Yes Yes Yes
Output ratings
Voltage 0 to 8 V 0 to 20 V 0 to 50 V 0 to 100 V
Current 0 to 10 A 0 to 5 A 0 to 2 A 0 to 1 A
Programming accuracy at 25°C ±5°C
Voltage 5 mV 10 mV 20 mV 50 mV
+ Current 0.05% + 4 mA 2 mA 1 mA 0.5 mA
Ripple and noise (20 Hz to 20 MHz, with outputs
ungrounded or with either terminal grounded)
Voltage normal mode rms 0.3 mV 0.3 mV 0.5 mV 0.5 mV
peak-to-peak 3 mV 3 mV 3 mV 3 mV
Fast mode rms 1 mV 1 mV 1 mV 2 mV
peak-to-peak 10 mV 10 mV 15 mV 25 mV
Current rms 3 mA 2 mA 2 mA 2 mA
DC measurement accuracy via GPIB or front panel
meters with respect to actual output at 25°C ±5°C
Voltage 0.03% + 2 mV 3 mV 6 mV 12 mV
Low current range –20 mA to +20 mA 0.1% + 2.5 A 2.5 A 2.5 A 2.5 A
High current range +20 mA to + rated I 0.2% + 1 mA 0.5 mA 0.25 mA 0.25 mA
–20 mA to –rated I 0.2% + 1.6 mA 1.1 mA 0.85 mA 0.85 mA
Load regulation
Voltage 2 mV 2 mV 4 mV 5 mV
Current 2 mA 1 mA 1 mA 1 mA
Line regulation
Voltage 0.5 mV 0.5 mV 1 mV 1 mV
Current 1 mA 0.5 mA 0.25 mA 0.25 mA
Transient response time Less than 100 s (50 s in the fast mode) for the output voltage to recover to its previous
level (within 0.1% of the voltage rating of the supply or 20 mV) following any step change in load current of up to
50% of the output current rating of the supply.
Understanding Linear Power Supply
Operation (AN1554)
5989-2291EN