Specifications
The Agilent Technologies N8700
series system DC power supplies
give you just the right performance —
at just the right price — in a compact
(2 U) package. This family of affordable
3300 W and 5000 W single-
output
programmable DC power supplies
consists of 21 models for simple
DC power applications.
They provide stable output power,
built-in voltage and current mea-
surement, and output voltage and
current from 8 V to 600 V and
5.5 A to 400 A.
Small, high-density package
The N8700 provides up to 5200 W
in a small space-saving 2U high,
19-inch wide package. Its air vents
are in the front and rear (not on
the top or bottom), so you can stack
other instruments directly above or
below it to save valuable rack space.
Flexible AC input voltage options
The N8700 models offer flexible
AC input voltage options. Every
N8700 model can be purchased
with either a 208 V 3-phase or
400 V 3-phase voltage input
option. The 3.3 kW models have
the additional option of a 230 V
single-phase AC input voltage.
Choose the one that best fits your
operating environment. They also
provide power factor correction.
Basic DC Power Supplies essential features for a tight budget
More detailed specifications at
www.agilent.com/find/N8700
32
21 Models: 3300 W and 5200 W output power
Up to 600 V and up to 400 A
Small, high density 2U package
Built-in voltage and current measurement
Full protection from over-voltage and over-current
Flexible AC input voltage options
LAN, USB, and GPIB interfaces standard
Fully compliant to LXI Core
N8731A - N8762A
N8740*
Single-Output
3.3-5.2 KW GPIB, LAN, USB, LXI Core
Specifications
(at 0° to 55°C unless
otherwise specified)
N8731A N8732A N8733A N8734A N8735A N8736A
Notes:
1
Minimum voltage is guaranteed to maximum 0.2% of rated output voltage.
2
Minimum current is guaranteed to maximum 0.4% of rated output current.
3
From no-load to full-load, constant input voltage. Maximum drop in remote sense.
4
For load voltage change equal to the unit voltage rating, constant input voltage
5
Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load.
3-Phase 400 V models: 342~460 VAC, constant load.
6
The constant current programming readback and monitoring accuracy does not include the
warm-up and load regulation thermal drift.
7
Time for output voltage to recover within 0.5% of its rated output for a load change
10 - 90% of rated output current, local sense.
* Rear panel with wire clamp connectors for 150 V to 600 V models (shown with 400 V 3-phase AC input option)
Number of outputs 1 1 1 1 1 1
GPIB, LAN, USB Yes Yes Yes Yes Yes Yes
Ouput Ratings
Voltage
1
8 V 10 V 15 V 20 V 30 V 40 V
Current
2
400 A 330 A 220 A 165 A 110 A 85 A
Power 3200 W 3300 W 3300 W 3300 W 3300 W 3400 W
Programming accuracy
Voltage
1
0.05%+ 4 mV 5 mV 7.5 mV 10 mV 15 mV 20 mV
Current
2, 6
0.1%+ 800 mA 660 mA 440 mA 330 mA 220 mA 170 mA
Output ripple and noise
CV p-p
(Up to 20 MHz) 60 mV 60 mV 60 mV 60 mV 60 mV 60 mV
CV rms
(From 5 Hz – 1 MHz) 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV
Measurement accuracy
Voltage 0.1%+ 8 mV 10 mV 15 mV 20 mV 30 mV 40 mV
Current
6
0.1%+
1200 mA 990 mA 660 mA 495 mA 330 mA 255 mA
Load effect
CV load regulation
3
6.2 mV 6.5 mV 7.25 mV 8 mV 9.5 mV 11 mV
CC load regulation
4
85 mA 71 mA 49 mA 38 mA 27 mA 22 mA
Source effect
CV line regulation
5
2.8 mV 3 mV 3.5 mV 4 mV 5 mV 6 mV
CC line regulation
5
42 mA 35 mA 24 mA 18.5 mA 13 mA 10.5 mA
Load transient recovery time
Time
7