Specifications

This series of 200 watt and
1000 watt DC power supplies
take the place of multiple power
supplies in your test system by
providing maximum power at a
variety of operating points.
Industry standard SCPI commands
andVXIPlug&Play drivers make
system integration easy. Using the
serial link, up to 16 power supplies
canbeconnectedthroughoneGPIB
address. These power supplies
have excellent electrical efficiency,
making them a good choice for
large systems.
Application notes
10 Hints for Using Your Power Supply
to Decrease Test Time
5968-6359E
10 Practical Tips You Need to
Know About Your Power Products
5965-8239E
Agilent DC Power Supplies
for Base Station Testing
5988-2386EN
Basic DC Power Supplies essential features for a tight budget
Specifications
(at to 55°C unless
otherwise specified)
6030A 6031A 6032A 6033A 6035A 6038A
More detailed specifications at
www.agilent.com/find/6030
24
Autoranging outputs provide maximum power at a variety
of operating voltages
Analog/resistance control of output voltage and current
Series and auto-parallel connections of multiple supplies
Built-in measurements and advanced programmable features
Protection features to ensure DUT safety
6030A, 6031A, 6032A, 6033A, 6035A, 6038A
Single-Output, Autoranging
200 W and 1000 W GPIB
Number of outputs 1 1 1 1 1 1
GPIB
Yes Yes Yes Yes Yes Yes
Output ratings
Output voltage 0 to 200 V 0 to 20 V 0 to 60 V 0 to 20 V 0 to 500 V 0 to 60 V
Output current 0 to 17 A 0 to 120 A 0 to 50 A 0 to 30 A 0 to 5 A 0 to 10 A
Maximum power watts 1,200 W 1,064 W 1,200 W 240 W 1,050 W 240 W
Auto-ranging output
V
1,
I
1
200 V, 5 A 20 V, 50 A 60 V, 17.5 A 20 V, 10 A 500 V, 2 A 60 V, 3.3 A
V
2
, I
2
120 V, 10 A 14 V, 76 A 40 V, 30 A 14 V, 17.2 A 350 V, 3 A 40 V, 6 A
V
3
, I
3
60 V, 17 A 7 V, 120 A 20 V, 50 A 6.7 V, 30 A 200 V, 5 A 20 V, 10 A
Programming accuracy Voltage 0.035% 0.035% 0.035% 0.035% 0.25% 0.035%
at 25°C ±5°C +145 mV +15 mV +40 mV +9 mV +400 mV +40 mV
Current 0.2% 0.25% 0.2% 0.15% 0.3% 0.09%
+25 mA +250 mA +85 mA +20 mA +63 mA +10 mA
Ripple and noise Voltage rms 22 mV 8 mV 8 mV 3 mV 50 mV 3 mV
20 Hz to 20 MHz p-p 50 mV 50 mV 40 mV 30 mV 160 mV 30 mV
Current rms 15 mA 120 mA 25 mA 30 mA 50 mA 5 mA
Readback accuracy Voltage 0.08% 0.08% 0.08% 0.07% 0.5% 0.07%
at 25°C ±5°C +80 mV +7 mV +20 mV +6 mV +200 mV +50 mV
Current 0.36% 0.4% 0.36% 0.3% 0.5% 0.2%
+15 mA +100 mA +35 mA +25 mA +50 mA +11 mA
Load regulation
Voltage 0.01%+ 5 mV 3 mV 5 mV 2 mV 40 mV 3 mV
Current 0.01%+ 0.01%+ 0.01%+ 0.01%+ 0.03%+ 0.01%+
10 mA 15 mA 10 mA 9 mA 34 mA 5 mA
Line regulation
Voltage 0.01%+ 0.01%+ 0.01%+ 0.01%+ 0.01%+ 0.01%+
5 mV 2 mV 3 mV 1 mV 13 mV 2 mV
Current 0.01%+ 0.01%+ 0.01%+ 0.01%+ 0.03%+ 0.01%+
5 mA 25 mA 10 mA 6 mA 17 mA 2 mA
Transient response time Time 2 ms 2 ms 2 ms 1 ms 5 ms 1 ms
10% step change Level 150 mV 100 mV 100 mV 50 mV 200 mV 7 5 mV
V
1
I
1
I
2
I
3
Volts
P
1
P
2
P
3
Amps
V
2
V
3
Autoranging Output: