Specifications
Specifications
(at 0° to 40°C unless
otherwise specified)
U8001A U8002A U8031A U8032A
Supplemental Characteristics (Non-warranted characteristics determined by design
that are useful in applying the product)
Voltage programming speed
Up full load 150 ms 150 ms 80 ms 200 ms
No load 100 ms 100 ms 80 ms 100 ms
Down full load 30 ms 30 ms 30 ms 30 ms
No load 450 ms 450 ms 150 ms 300 ms
Last memory setting enabled Yes Yes Yes Yes
17
Power that’s suitable for your
application requirements
The U8000 Series with total power
ranging from 90 W to 375 W provides
performance that is suitable for elec-
tronics manufacturing for computers
and peripherals, communication
systems and peripherals, aircraft/
avionics systems, electronic compo-
nents, and more. The U8000 Series
complements the Agilent E3600 DC
power supplies family to provide
a wider range of power source
alternatives.
Differentiated features typically found
only in programmable power supplies
The U8000 Series offers fully inte-
grated over voltage protection (OVP)
and over current protection (OCP) to
prevent damage to the device-under-
test (DUT). Using the capability to
save and recall three memory states,
you can minimize errors and reduce
set-up time. The U8000 Series also
provides security features such as
keypad lock to prevent measurement
errors due to accidental front panel
usage. When the keypad lock is
activated, the knob and all the but-
tons on the front panel are disabled
except the keypad lock button. The
physical lock mechanism found at
the rear panel of the power supply
provides secure instrument storage.
The LCD display with backlight
on/off options enables brighter
display for data viewing.
Single & Triple Output: 90-375 W (Continued)
More detailed specifications at
www.agilent.com/find/lowcostpower
Basic DC Power Supplies essential features for a tight budget
Solid, reliable performance in its class
The U8000 Series provides excellent
load and line regulation (Constant
Voltage, CV: < 0.01% +2 mV; Constant
Current, CC: < 0.02% +2 mA) to
ensure stable output even when the
load changes. With the fast 50 sec
transient response, test times and
manufacturing cost are significantly
reduced. The U8000 Series comes
with low output noise of 1 mVrms,
3 mArms from 20 Hz to 20 MHz,
providing clean output and minimiz-
ing the interference in the DUT.
Supplemental characteristics
for all model numbers
Size: U8001A, U8002A:
212.3 mm W x 88.1 mm H x 394.3 mm D
(8.4 in x 3.5 in x 15.5 in);
U8031A-U8032A:
212.3 mm W x 179.0 mm H x 379.0 mm D
(8.4 in x 7.0 in x 14.9 in);
Weight:
U8001A: 7.3 kg (16.1 lbs)
U8002A: 8.3 kg (18.3 lbs)
U8031A, U8032A: 8.2 kg (18.1 lbs)
Warranty: Three years
Ordering information
Opt 0E9: 90 to 110 Vac, 47 to 63 Hz
Opt 0EM: 104 to 126 Vac, 47 to 63 Hz
Opt 0E3: 207 to 253 Vac, 47 to 63 Hz
Opt UK6: Commercial calibration
with test result data
Accessories
34190A Rack mount kit including
filler panel
1
The specifications referenced in this section are for Output Channel 3 (5 V fixed output). All other
specifications listed for the U8031A and U8032A in this table are intended for Output Channel 1 and 2.
2
Specifications are based on one hour warm-up period