Specifications

Number of outputs 3 3
Output ratings (at 0 °C to 50 °C)
Voltage –20 V to 20 V –20 V to 20 V
Current –120 mA to 120 mA –120 mA to 120 mA
Performance specification
Voltage programming 12 months (at 25 °C ± 3 °C), ±(% of output + offset)
Accuracy
1
Range ±2 V 0.075% + 1.5 mV 0.075% + 1.5 mV
Range ±20 V 0.05% + 10 mV 0.05% + 10 mV
Resolution Range ±2 V 0.1 mV 0.1 mV
Range ±20 V 1 mV 1 mV
Current programming 12 months (at 25 °C ± 3 °C), ±(% of output + offset)
Accuracy
1
Range ±1 µA 0.085% + 0.85 nA 0.085% + 0.85 nA
Range ±10 µA 0.085% + 8.5 nA 0.085% + 8.5 nA
Range ±100 µA 0.075% + 75 nA 0.075% + 75 nA
Range ±1 mA 0.075% + 750 nA 0.075% + 750 nA
Range ±10 mA 0.075% + 7.5 µA 0.075% + 7.5 µA
Range ±120 mA 0.1% + 100 µA 0.1% + 100 µA
Resolution Range ±1 µA 100 pA 100 pA
Range ±10 µA 1 nA 1 nA
Range ±100 µA 10 nA 10 nA
Range ±1 mA 100 nA 100 nA
Range ±10 mA 1 µA 1 µA
Range ±120 mA 20 µA 20 µA
Three-channel, four-quadrant
(±20 V, ±120 mA)
The U2722A/U2723A three-
channel SMU is a versatile device
that allows you to perform sweep
and measurement from different
operating regions without needing
extra configurations. The four
quadrant operation makes the
U2722A/U2723A SMU well
suited for a wide range of test
applications, including leakage
measurement, solar cell measure-
ment, forward/reverse voltage
and IV curve tracing.
Increase the efficiency of your tests
With a high measurement
sensitivity of 100 pA at 16-bit
resolution for pico-level mea-
surement and 0.1% accuracy, the
U2722A/U2723AUSBmodular
source measure unit provides
more detailed and accurate
analysis and measurement results.
U2722A/U2723A supports SCPI
and IVI-COM. The SMU is com-
patible with a wide range of
Application Development
Environments, minimizing your
work time and increasing your
software options. Save time and
effort with the bundled Agilent
Measurement Manager (AMM)
software, which coverts SCPI
commands into snippets of VEE,
VB,C++andC#codewiththe
command logger function.
Application Specific DC Power Supplies tailored solutions for specific needs
More detailed specifications at
www.agilent.com/find/U2722A
www.agilent.com/find/U2723A
142
3-Channel source measure unit
4-Quadrant (±20 V)
High current sensitivity of 100 pA with 16 bit resolution
0.1% basic accuracy
Low current measurement capability down to nA levels
Voltage and current programming/readback
High-speed USB 2.0, USBTMC-USB488 standard
(compatible with Microsoft® Windows® operating systems only.)
Standalone and modular capabilities
U2700
Source Measure Units
U2700 Series USB Modular Source Measure Units
Specifications
(at 0° to 55°C unless
otherwise specified)
U2722A U2723A
1
Accuracy measurments are based on NPLC 10.