Specifications

138
and insights into power consump-
tion by enabling engineers to see
the complete current waveform they
have never seen before, from nA to
A, in one pass and one picture.
Designed for both R&D and Automated
Test Environments (ATE)
The new SMUs are a part of the
N6700 modular power system,
which consists of the N6700 low-
profile mainframes for ATE and
the N6705 DC power analyzer
mainframe for R&D. The product
family has four mainframes and
more than 30 DC power modules to
choose from providing a complete
spectrum of solutions, from R&D
through design validation and
manufacturing.
Key features
Apply to all models unless other-
wise noted
•Seamless,dynamicmeasurements
down to nA and µV (N6781A and
N6782A only)
•Glitch-free operation – change
sourcing ranges or measurement
ranges without any glitches
•Fourcurrentprogramming
ranges – precisely source current
down to µA (N6784A only)
•Excellenttransientresponse
for stable output voltage with
dynamic loads
•2-quadrantoperation–useas
an advanced power supply or
electronic load (N6781A and
N6782A only)
•4-quadrantoperation–useas
an advanced bipolar power supply
or bipolar electronic load
(N6784A only)
•Stableoperationwithcapacitive
loads up to 150 µF
Source Measure Units
N6780 Series Source/Measure Units (Continued)
More detailed specifications at
www.agilent.com/find/N6781A
www.agilent.com/find/N6782A
www.agilent.com/find/N6784A
Application Specific DC Power Supplies tailored solutions for specific needs
SMU Module
Specifications
N6781A N6782A N6784A
Programming accuracy
(At 23 °C ±5 °C after 30 min. warm-up. Applies from minimum to maximum programming range at any load.)
Current, 100 mA range 0.03% + N/A N/A 12 µA
Current, 10 mA range 0.025% + N/A N/A 5 µA
Resistance 0.1% + 3 mΩ N/A N/A
(in 20 V output range)
Resistance 0.1% + 1.5 mΩ N/A N/A
(in 6 V output range)
Measurement accuracy
(at 23 °C ±5 °C)
Voltage, 20 V range 0.025% + 1.2 mV 1.2 mV 1.2 mV
Voltage, 1 V range 0.025% + 75 µV 75 µV 75 µV
Voltage, 100 mV range 0.025% + 50 µV 50 µV 50 µV
Current, 3 A range 0.03% + 250 µA 250 µA 250 µA
Current, 100 mA range 0.025% + 10 µA 10 µA 10 µA
Current, 1 mA range 0.025% + 100 nA 100 nA 100 nA
Current, 10 µA range 0.025% + 8 nA 8 nA 8 nA
Load transient response time – voltage priority
In the 20 V output range: the time to recover to within the settling band for a load change from
0.1 A to 0.5 A.
In the 6 V output range: the time to recover to within the settling band for a load change from 0.1 A to 1.5 A.
Voltage settling band ± 10 mV ± 10 mV ± 10 mV
(20 V output range)
Voltage settling band ± 20 mV ± 20 mV ± 20 mV
(6 V output range)
Recovery time ≤ 35 µs ≤ 35 µs ≤ 35 µs
•High-speed output can slew at
10 V per µs into a resistive load
•FastmodulationofDCoutput–
create arbitrary waveforms up to
100 kHz (sine) into a resistive load
•
High-speed digitized measurements
capture/view the power consumption
of the DUT up to every 5 µs with
built-in 200 kHz digitizer
•Auxiliaryvoltagemeasurement
input
for battery run down test
(N6781A only)
•Programmableoutputresistance
from -40 mΩ to +1 Ω to simulate
internal resistance of a battery
(N6781A only)