Specifications
Specifications
(at 0° to 55°C unless
otherwise specified)
N6761A N6763A N6764A N6783A N6781A N6784A
N6762A N6765A N6766A -BAT N6782A
Note
Output ratings
Voltage
50 V 20 V 60 V 8 V
+20 V ±20 V
Current
1.5 A 50 A 20 A +3 A
±
3 A
±
3 A
3 A 17 A -2 A
Power 50 W 300 W 300 W 24 W 20 W 20 W
100 W 500 W 500 W
Autoranging
Yes Yes Yes No No No
Measurement accuracy
Voltage 0.016% + 0.03% + 0.03% + 0.05% + 0.025% + 0.025% +
6 mV 10 mV 25 mV 5 mV 1.2 mV 1.2 mV
Current 0.04% + 0.1% + 0.1% + 0.1% + 0.03% + 0.03% +
160 A** 10 mA 5 mA 600 A 250 A 250 A
Noise (20 Hz to 20 MHz)
0.35 mVrms
1 mVrms
1 mVrms
1.5 mVrms 1.2 mVrms 1.2 mVrms
4.5 mVpp 5 mVpp 6 mVpp 8 mVpp 12 mVpp 12 mVpp
Polarity reverse relays Not Not Not Not Not Not
available available available available available available
Output relays Optional Optional Optional Optional Available Available
**0.5% + 100 nA with Option 2UA
Scope: Up to 100 kHz digitizer for N673x, N674x, N675x, N676x, N677x, and N6783 modules;
Up to 200 kHz for N678x SMUs
ARB: Approx max bandwidth = 5 kHz for N675x and N676x modules; 500 Hz for N673x, 4x, 7x, and 83 modules;
100 kHz for N678x SMUs
Note: Requires special installation. Instructions ship with the module.
119
The Agilent N6705 DC power
analyzer saves time
• Provides unrivaled productivity
gains for sourcing and measuring
DC voltage and current into your
DUT by integrating up to four
advanced power supplies with
DMM, scope, arb, and data logger
features.
• Eliminates the need to gather
multiple pieces of equipment,
create complex test setups including
transducers (such as current probes
and shunts) to measure current
into your DUT.
• Eliminates the need to develop
and debug programs to control a
collection of instruments and take
useful measurements because all
the functions and measurements
are available at the front panel.
Agilent N6705 DC power analyzer
makes these tasks easy, right from
the front panel
• Setup and view critical turn-on/
turn-off sequences
• Measure and display voltage,
current versus time to visualize
power into the DUT
• Control DC bias supply ramp-up/
down rates
• Generate DC bias supply
transients and disturbances
• Log data for seconds, minutes,
hours, or even days to see current
consumption or capture anomalies
• Save data and screen shots to
internalstorageorexternalUSB
memory devices
• Save and name your setup and
tests for easy re-use
• Share setups with colleagues
Modular DC Power Analyzer
600 W GPIB, LAN, USB, LXI Core
(Continued)
More detailed specifications at
www.agilent.com/find/N6705B
High Performance DC Power Supplies speed and accuracy for test optimization
New 14585A control and analysis
software saves even more time
The new 14585A Control and
Analysis Software is a companion
PC application that gives you
control of up to four N6705 main-
frames from a single PC control
screen. With this software, you
get improved data visualization
and data management.
Visit
www.agilent.com/find/14585