System Diagnostics 93Chapter 5
Using Agilent TestExec SL to Run the Testplan
Use TestExec SL to select and run the following testplan to perform the
system diagnostics:
C:\Program Files\Agilent\TS-5400 System Software\testplan\dgn\Dgn.tpa
Executing the
Testplan
To Execute a testplan select ‘Debug’ then ‘Go’ or press F5 or press .
Diagnostics will begin executing and report any errors it finds. Answer any
questions as appropriate to continue execution.
Hardware
Configuration
Details
If a system diagnostic test generates a hardware failure, the problem may be
caused by an unrecognized module in the system. You can use the
‘
system.ust’ file to determine which hardware is recognized in the
system. This file also lists aliases and wiring descriptions.To select the file,
select ‘
View’, ‘Listing’, ‘Hardware Configuration’, and ‘System
Layer
’, as shown in Figure 5-1. See Figure 5-2 for typical hardware listings.
Note that the listing includes the module description, location, logical
address, and other pertinent information. Use this data to determine that all
modules in the system are recognized.
Figure 5-1. Selecting the system.ust Listing
1. Click on “View”
2. Click on “Listing”
3. Click on “Hardware Configuration”
4. Click on “System Layer”