Specifications
92 System Diagnostics Chapter 5
AVERTISSEMENT Lors du dépannage, il est probable que des tensions pouvant
causer des blessures ou la mort soient présentes. Le
dépannage ne doit étre confié qu’à un personnel d’entretien
qualifié.
Caution To prevent electrostatic discharge (ESD): from damaging
sensitive system components, always wear a grounded,
anti-static wrist strap when working on the system
Diagnostics Strategy
Two diagnostic testplans were developed for your test system at the factory.
Dgn.tpa does not require a test fixture and performs self-tests and
communications tests on the system instrumentation. Cedgn.tpa requires an
optional test fixture and performs more extensive loopback testing on the
system. Both testplans are located in:
C:\Program Files\Agilent\TS-5400 System Software\testplan\dgn
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com