Specifications
60 Customizing the System Chapter 3
Set<xxx> ‘Set’ prefix is used to set up given configuration
to the device.
Reset Resets instrument(s) to their power-on state.
Clear Clears errors and output buffers.
Initiate Puts instrument in ‘wait for trigger’ state.
Necessary for external trigger modes requiring
continuation of the program after this command
is issued to generate the trigger. May also be
used to start an immediate reading cycle to be
followed by a ‘GetResults’ call.
Trigger Generates a software trigger immediately.
IsSet Returns true or false regarding the busy/ready
state of the instrument. This may or may not be
blocking, depending upon the capability of the
given instrument.
Connect Connects output relays.
Connect<xxx> Connects a specific relay.
Disconnect Disconnects output relays.
Disconnect<xxx> Disconnects a specific relay.
List of Setup functions (executed in memory - not output to device)
Conf<xxx> Configure specified information.
ConfCal Select mode based on calibration constants,
such as 50/60 Hz.
ConfSync Enables synchronization of multiple
instruments on a given interface (if allowed by
the instruments). For example, a card
containing dual arbitrary waveform generators
could be set up to generate simultaneous output
from both generators.
ConfSample Sets up sample parameters.
ConfTrigOut Sets up the trigger output parameters.
ConfTrigIn Sets up the trigger input parameters.
ConfInControls Sets input-related switches, such as filters and
attenuators.
ConfOutControls Sets output-related switches, such as the output
impedance
Return<xxx> Returns specified data from memory.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com