User`s guide

Language Dictionary - 8
89
Table 8-1. Subsystem Commands Syntax (continued)
OUTPut
[:STATe] <bool>
Enables/disables the dc source output
:TYPE [:CAPacitance] <setting>
Sets output capacitor compensation (HIGH | LOW)
:DFI
[:STATe] <bool>
Enables/disables the DFI output
:SOURce <source>
Selects event source (QUES | OPER | ESB | RQS | OFF)
:PON
:STATe <state>
Set power-on state (*RST | RCL0)
:PROTection
:CLEar
Reset latched protection
:DELay <n>
Delay after programming/before protection
:RI
:MODE <mode>
Sets remote inhibit input (LATC | LIVE | OFF)
SENSe
:CURRent
[:DC]
RANGe [:UPPer] <n>
Selects the high current measurement range
:DETector <detector>
Selects the current measurement detector (ACDC | DC)
:FUNCtion <function>
Configures the measurement sensor ("VOLT" | "CURR")
:PROTection
:STATe <state>
Enables/disables open sense lead detection
:SWEep
:OFFSet
:POINts <n>
Defines the offset in the data sweep
:POINts <n>
Define the number of data points in a sweep
:TINTerval <n>
Sets the digitizer sample spacing
:WINDow [:TYPE] <type>
Sets the measurement window function (HANN | RECT)
[SOURce:]
CURRent
[:LEVel]
[:IMMediate][:AMPLitude] <n>
Sets the output current level
:TRIGgered [:AMPLitude] <n>
Sets the triggered output current level
:PROTection
:STATe <bool>
Enables/disables current limit protection
DIGital
:DATA [:VALue] <n>
Sets and reads the digital control port
:FUNCtion <function>
Configures digital control port (RIDF | DIG)
VOLTage
[:LEVel]
[:IMMediate][:AMPLitude] <n>
Sets the dc voltage level
:TRIGgered [:AMPLitude] <n>
Sets the transient voltage level
:PROTection
[:LEVel] <n>
Sets the overvoltage protection threshold
:STATe <bool>
Enables/disables overvoltage protection