User`s guide

5 – Front Panel Operation
54
4 - Programming External Protection and the Digital Port Functions
Your dc source is shipped with the output port function set to RIDFI mode. In this mode the port
functions as a remote inhibit input with a discrete fault indicator output signal. You can also configure
the port to act as a Digital Input/Output device.
To configure the RIDFI mode of the port, proceed as follows:
Action Display
1.
On the Function keypad, press Output.
*RST
2. Scroll through the Output menu by pressing q. The PORT command lets you select
either the RIDFI or the DIGIO function. Press Enter when done.
PORT RIDFI
3. Scroll to the RI command to configure the Remote INHibit indicator. Use the ã
and ä keys to select either LIVE or LATCHING, either of which enable the RI
indicator. Then press Enter. With RI enabled, a low-true on the INH input will
disable the output of the unit. LIVE causes the output of the unit to track the state of
the INH input. LATCHING latches the output of the unit off in response to the
inhibit signal.
RI LIVE
RI LATCHING
4. Access the Output menu again and scroll through the menu. The DFI command lets
you enable the Discrete Fault Indicator. Use the ä key and select ON to enable the
FLT output. Then press Enter. With the FLT output enabled, the open-collector
logic signal can be used to signal external devices when a fault condition is
detected.
DFI ON
5. Scroll to the DFI:SOUR command to select the internal source that drives this
signal. Use the ä key to select from the RQS or ESB bits, or the Operation or
Questionable status registers. Then press Enter. Status summary bits are explained
in chapter 7.
DFI:SOUR RQS
DFI:SOUR ESB
DFI:SOUR OPER
DFI:SOUR QUES
To configure the DIGIO mode of the port, proceed as follows:
Action Display
1.
On the Function keypad, press Output.
*RST
2. Scroll through the Output menu by pressing q. The PORT command lets you select
either the RIDFI or the DIGIO function. Press Enter when done.
PORT DIGIO
3. Scroll to the DIGIO command to set and read the Digital Input/Output Port. Press
Enter Number and enter a number from 0 to 7 to program the three bits (0
programs all bits low; 7 programs all bits high). Press Enter when done.
DIGIO 5
5 - Setting the GPIB Address and RS-232 Parameters
Your dc source is shipped with the GPIB address set to 5. This address can only be changed from the
front panel using the Address menu located under the
Address key. This menu is also used to select the
RS-232 interface and specify RS-232 parameters such baud rate and parity.
Set the GPIB address as follows:
Action Display
1.
On the System keypad, press Address.
ADDRESS 5
2.
Enter the new address. For example, Press Enter Number, 7, Enter.
ADDRESS 7
Configure the RS-232 interface as follows: