User`s guide
5 – Front Panel Operation
48
Output Control Keys
Output control keys control the output functions of the dc source.
Press this key to access the voltage menu.
Display Command Function
VOLT <value> Sets the output voltage
Press this key to access the current menu.
Display Command Function
CURR <value> Sets the output current
Press this key to access the output menu list.
Display Command Function
*RST Places the dc source in the factory-default state
PON:STATE <char> Select the power-on state command (RST or RCL0)
1
RI <char> Sets the remote inhibit mode (LATCHING, LIVE, or OFF)
1
DFI <char> Sets the discrete fault indicator state (ON or OFF)
DFI:SOUR <char> Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)
2
PORT <char> Sets the output port functions (RIDFI or DIGIO)
1
DIGIO <char> Sets and reads the I/O port value (0 through 7)
PROT:DLY <value> Sets the output protection delay in seconds
TYPE:CAP <char> Sets the output compensation (HIGH or LOW)
1
Press this key to display protection status.
Display Command Function
OVER CURRENT Status of the protection features (example shows overcurrent)
NO FAULT Status of the protection features (example shows none tripped)
Press this key to access the overvoltage protection menu.
Display Command Function
PROT:STAT <char> Enables or disables overvoltage protection (ON or OFF)
PROT:LEV <value> Sets the overvoltage protection level
This key accesses the calibration menu (Refer to Appendix B for details).
Notes:
1
These parameters are stored in non-volatile memory
2
These status summary bits are explained in chapter 7
value = a numeric value
char = a character string parameter
Use and to scroll through the menu commands.
Use and to scroll through the menu parameters.
Use and to select a digit in a numeric entry field.
qp
ã ä
á â
Voltage
Current
Output
Protect
OVShift
CalShift