User`s guide
Turn-On Checkout - 4
41
In Case of Trouble
Dc source failure may occur during power-on selftest or during operation. In either case, the display may
show an error message that indicates the reason for the failure.
Selftest Error Messages
Pressing the Shift, Error keys will show the error number. Selftest error messages appear as: ERROR
<n> where "n" is a number listed in the following table. If this occurs, turn the power off and then back
on to see if the error persists. If the error message persists, the dc source requires service.
Table 4-1. Power-On Selftest Errors
Error No. Failed Test
Error 0 No error
Error 1 Non-volatile RAM RD0 section checksum failed
Error 2 Non-volatile RAM CONFIG section checksum failed
Error 3 Non-volatile RAM CAL section checksum failed
Error 4 Non-volatile RAM STATE section checksum failed
Error 5 Non-volatile RST section checksum failed
Error 10 RAM selftest
Error 11 to 14 VDAC/IDAC selftest 1 to 4
Error 15 OVDAC selftest
Error 80 Digital I/O selftest error
Runtime Error Messages
Appendix C lists other error messages that may appear at runtime. Some of these messages will also
appear on the front panel when the Prot key is pressed. To clear the error, you must remove the condition
that caused the error and then press the Prot Clear key.
Table 4-2. Runtime Error Messages
Error Description
Overvoltage an overvoltage condition has occurred
Overcurrent an overcurrent condition has occurred
Overtemperature an overtemperature condition has occurred
Remote inhibit a remote inhibit signal has been applied to the RI input
+ sense open positive sense lead is open
- sense open positive sense lead is open
+/- sense open positive and negative sense lead is open
sense open incorrect voltage reading on the sense leads, the unit may need to be recalibrated
If the front panel display shows OVLD , this indicates that the output voltage or current is beyond the
range of the meter readback circuit. If this is the case, check that the setting of the output compensation is
correct for the phone you are testing. If the front panel display indicates -- -- -- -- -- , an GPIB
measurement is in progress.