Front Panel Menus - At a Glance
ADDRESS 7
Sets the GPIB Address
INTF GPIB
Selects an interface (GPIB or RS232)
BAUDRATE 300
Selects baud rate (300, 600, 1200, 2400, 4800, 9600)
PARITY NONE
Selects message parity (NONE, EVEN, ODD, MARK, SPACE)
FLOW NONE
Selects flow control (XON-XOFF, RTS-CTS, DTR-DSR, NONE)
LANG SCPI
Selects language (SCPI or COMP)
REMOTE FP OFF
Enables or disables Agilent 14575A front panel interface (ON or OFF)
*RCL 0
Recalls instrument state
*SAV 0
Saves present instrument state
ERROR 0
Displays errors in SCPI error queue
12.000V 0.204A
Measures output voltage and current
12.500V MAX
Measures peak output voltage
1
1.000V MIN
Measures minimum output voltage
1
12.330V HIGH
Measures the high level of a voltage pulse waveform
1
0.080V LOW
Measures the low level of a voltage pulse waveform
1
12.000V RMS
Measures rms voltage
1
0.350A MAX
Measures peak output current
1
0.050A MIN
Measures minimum output current
1
0.400A HIGH
Measures the high level of a current pulse waveform
1
0.012A LOW
Measures the low level of a current pulse waveform
1
0.210A RMS
Measures rms current
1
VOLT 20.000
Sets the output voltage
CURR 2.000
Sets the output current
OVERCURRENT
Protection status (example shows overcurrent tripped)
*RST
Places the dc source in the factory-default state
PON:STATE RST
Select the power-on state command (RST or RCL0)
PROT:DLY 0.08
Sets the output protection delay in seconds
SENSE:PROT ON
Sets the broken sense lead detect circuit on
RI LATCHING
Sets the remote inhibit mode (LATCHING, LIVE, or OFF)
DFI OFF
Sets the discrete fault indicator state (ON or OFF)
DFI:SOUR OFF
Selects the DFI source (QUES, OPER, ESB, RQS, or OFF)
PORT RIDFI
Sets the output port functions (RIDFI or DIGIO)
DIGIO 7
Sets and reads the I/O port value (0 through 7)
TYPE:CAP LOW
Sets the output capacitance compensation (HIGH or LOW)
VOLT:PROT 22
Sets the overvoltage protection level
PROT:STAT ON
Enables or disables overvoltage protection (ON or OFF)
CURR:RANG HIGH
Sets the current range (HIGH, LOW, or AUTO)
1
CURR:DET ACDC
Sets the current measurement detector (ACDC or DC)
1
TINT 46.8
Sets the time interval for a front panel measurement in seconds
POINT 2048
Sets the buffer size for a front panel measurement
CAL ON
Accesses calibration menu (See Appendix B).
Use and to select parameters (table shows factory defaults). Use to exit any menu.