User`s guide

Specifications - A
135
Table A-2. Supplemental Characteristics (continued)
Parameter Agilent 66111A Agilent 66311B
Measurement Time
(includes 30 ms
1
data
acquisition time and 20 ms data
processing overhead)
voltage or current 50 ms average
Command Processing Time
(time for output to begin to
change following receipt of
digital data)
4 ms average
Remote Sense Capability
(per load lead)
Up to 4 V
(add 2 mV to the voltage load regulation
specification for each 1 V change in the
+ output lead due to load current change.)
Savable Instrument States
(applies only in SCPI mode)
4 (in locations 0 to 3)
RS-232 Interface Capabilities
Baud rates:
Data formats:
Language:
300 600 1200 2400 4800 9600
7 bits even or odd parity; 8 bits without parity SCPI
or COMPatibility
2
GPIB Interface Capabilities
Language:
Interface:
SCPI or COMPatibility
2
AH1, C0, DC1, DT1, E1, L4, PP0, RL1, SH1, SR1,
T6
INH/FLT Characteristics
Maximum ratings:
FLT Terminals:
INH Terminals:
16.5 Vdc between terminals 1 and 2; 3 and 4; and
from terminals 1 or 2 to chassis ground
Low-level output current = 1.25 mA max.
Low-level output voltage = 0.5 V max.
Low-level input voltage = 0.8 V max.
High-level input voltage = 2 V min.
Low-level input current = 1 mA
Pulse width = 100 ยตs min.
Time delay = 4 ms typical
Digital I/O Characteristics
Maximum ratings:
Digital OUT Port 0,1,2
(open collector)
Digital IN Port 2:
(internal pull-up)
same as INH/FLT Characteristics
Output leakage @ 16V = 0.1 mA (ports 0,1)
= 12.5 mA (port 2)
Output leakage @ 5V = 0.1 mA (ports 0,1)
= 0.25 mA (port 2)
Low-level output sink current @ 0.5 V = 4 mA
Low-level output sink current @ 1 V = 50 mA
Low-level input current @ 0.4 V = 1.25 mA
High-level input current @ 5 V = 0.25 mA
Low-level input voltage = 0.8 V max.
High level input voltage = 2.0 V min.
1
May be reduced by changing the default conditions of 2048 data points but measurement uncertainty due to noise will increase.
2
COMPatibility language is used to program the Agilent 663xA Series power supplies. Not all Agilent 66111A/66311B
capabilities are available when using the COMPatibility language.