User`s guide

Language Dictionary - 8
127
*RST
This command resets the dc source to a factory-defined state as defined in the following table. *RST also
forces an ABORt command.
Table 8-8. *RST Settings
CAL:STAT OFF [SOUR:]CURR 10% of MAX*
DIG:DATA 0 [SOUR:]CURR:TRIG 10% of MAX*
DISP:STAT ON [SOUR:]CURR:PROT:STAT OFF
DISP:MODE NORM [SOUR:]LIST:COUN 0
DISP:TEXT “ “ [SOUR:]VOLT 0
INIT:CONT OFF [SOUR:]VOLT:TRIG 0
OUTP OFF [SOUR:]VOLT:PROT MAX*
OUTP:DFI OFF [SOUR:]VOLT:PROT:STAT ON
OUTP:DFI:SOUR OFF TRIG:ACQ:COUN:CURR 1
OUTP:PROT:DEL .08 TRIG:ACQ:COUN:VOLT 1
OUTP:PROT:STAT ON TRIG:ACQ:HYST:CURR 0
OUTP:TYPE LOW TRIG:ACQ:HYST:VOLT 0
SENS:CURR:RANG MAX TRIG:ACQ:LEV:CURR 0
SENS:CURR:DET ACDC TRIG:ACQ:LEV:VOLT 0
SENS:FUNC VOLT TRIG:ACQ:SLOP:CURR POS
SENS:SWE:OFFS:POIN 0 TRIG:ACQ:SLOP:VOLT POS
SENS:SWE:POIN 2048 TRIG:ACQ:SOUR INTERNAL
SENS:SWE:TINT 15.6 µs
TRIG:TRAN:SOUR BUS
Command Syntax
*RST
Parameters
None
Related Commands
*PSC *SAV
*SAV
This command stores the present state of the dc source to the specified location in non-volatile memory.
Up to 4 states can be stored. If a particular state is desired at power-on, it should be stored in location 0.
It will then be automatically recalled at power turn-on if OUTPut:PON:STATe is set to RCL0. *RCL
retrieves instrument states.
Command Syntax
*SAV <NRf>
Parameters
0 | 1 | 2 | 3
Example
*SAV 3
Related Commands
*RCL *RST