User`s guide

A - Specifications
50
Supplemental Characteristics
Table A-2 lists the supplemental characteristics, which are not warranted but are descriptions of typical
performance determined either by design or type testing.
Table A-2. Supplemental Characteristics
Parameter Agilent 6611C Agilent6612C
Agilent 66312A
Agilent 6613C Agilent 6614C
Input Rating 100 Vac mains:
47 – 63 Hz (87-106 Vac)
(at full load)
115 Vac mains:
(104-127 Vac)
220 Vac mains:
(191-233 Vac)
230 Vac mains:
(207-253 Vac)
2.2 A, 120 W
2 A, 120 W
1.1 A, 120 W
1 A, 120 W
1.6 A, 100 W
1.4 A, 100 W
0.8A, 100 W
0.75 A, 100 W
1.6 A, 100 W
1.4 A, 100 W
0.8A, 100 W
0.75 A, 100 W
1.6 A, 100 W
1.4 A, 100 W
0.8A, 100 W
0.75 A, 100 W
Output Programming Voltage:
Range Currrent:
OVP:
0 – 8.190 V
0 – 5.118 A
12 V
0 – 20.475 V
0 – 2.0475 A
0 – 22 V
0 – 51.188 V
0 – 1.0238 A
0-55 V
0 - 102.38 V
0 – 0.5118 A
0 – 110 V
Average Programming Voltage:
Resolution Current:
OVP:
2 mV
1.25 mA
60 mV
5 mV
0.5 mA
100 mV
12.5 mV
0.25 mA
250 mV
25 mV
0.125 mA
500 mV
OVP Accuracy 2.4 % +
200 mV
1
240 mV 600 mV 1.2 V
Maximum Current Measurement 7 A 2.43 A 1.28 A 0.7 A
Average Current High Range:
Measurement Low Range:
Resolution
213 uA
0.6 uA
74 uA
0.6 uA
39 uA
0.6 uA
21 uA
0.6 uA
Sink Current
2
- 3 A - 1.2 A - 0.6 A - 0.3 A
Programming Accuracy Voltage: 0.01% +
Temperature Coefficient Current: 0.01% +
(change/ C
O
) OVP: 0.015% +
0.15 mV
30 uA
2 mV
0.25 mV
12 uA
4 mV
0.5 mV
6 uA
10 mV
1 mV
3 uA
20 mV
Readback Accuracy Voltage: 0.01% +
Temperature Coefficient
(change/C
O
) Current (DC): 0.02% +
Current (ACDC): 0.05% +
Current (Low Range): 0.01% +
60 uV
25 uA
160 uA
0.3 uA
150 uV
10 uA
80 uA
0.3 uA
500 uV
5 uA
40 uA
0.3 uA
700 uV
3 uA
20 uA
0.3 uA
Drift
3
Voltage: 0.01% +
Current: 0.01% +
0.25 mV
50 uA
0.5 mV
20 uA
1 mV
10 uA
1 mV
10 uA
Output Voltage Rise/Fall Time
(for a change from 10% to 90% or
90% to 10% of the total excursion)
2 ms
Output Voltage Settling Time
(to settle within 1 LSB or 0.025% times
the rated voltage of the final value)
6 ms
1
Agilent 6611C Option 760 = 2.4% + 500mV.
2
The sink current does not track the programmed current.
3
Following a 30 minute warm-up, the change in output over 8 hours, under constant ambient, load and line operating conditions.