Technical data

(per phase for a sine wave with a resistive load at 0º to 40º C, within an output frequency range of 45 Hz to
1000Hz, and in ac coupled mode after a 30 minute warm-up unless otherwise noted. Note: For 6814B and
6834B output voltage must be at least 50% of range.)
1
SPECIFICATIONS (CONTINUED)
(per phase for a sine wave with a resistive load at 0º to 40º C, within an output frequency range of 45 Hz to 1000Hz,
and in ac coupled mode after a 30 minute warm-up unless otherwise noted. Note: For 6814B and 6834B output voltage
must be at least 50% of range.)
1
SPECIFICATIONS
Programming accuracy (25˚± 5˚ C)
44 AGILENT ac POWER SOLUTIONS
ac Power Solutions (cont’d)
Visit our web site
http://www.agilent.com/find/power
A
B
C
D
E
F
H
ac Power
Solutions
(Maximum)
For a complete list of specifications for Agilent’s ac power solutions, please see the operating manual on our web site at
http:// www.agilent.com/find/manuals
6811B 6812B 6813B 6814B 6834B
Number of Phases 1 1 1 1 1/3
RMS Voltage 0.15% + 0.3 V 0.15% + 0.3 V 0.15% + 0.3 V 0.15% + 0.3 V 0.15% + 0.3 V
(% of output + offset) (45 - 100Hz) (45 - 100Hz) (45 - 100Hz) (45 - 100Hz) (45 - 100Hz)
0.5% + 0.3 V 0.5% + 0.3 V 0.5% + 0.3 V 0.5% + 0.3 V 0.5% + 0.3 V
(>100 - 500 Hz) (>100 - 500 Hz) (>100 - 500 Hz) (>100 - 500 Hz) (>100 - 500 Hz)
1% + 0.3 V 1% + 0.3 V 1% + 0.3 V 1% + 0.3 V 1% + 0.3 V
(> 500 - 1000 Hz) (> 500 - 1000 Hz) (> 500 - 1000 Hz) (> 500 - 5000 Hz) (> 500 - 5000 Hz)
DC voltage 0.1% + 0.5 V 0.1% + 0.5 V 0.5% + 0.3 V N/A N/A
Frequency 0.01% + 10µHz 0.01% + 10µHz 0.01% + 10µHz 0.01% + 10µHz 0.01% + 10µHz
3 Phase Mode N/A N/A N/A N/A 0.1˚ (45 - 100 Hz)
(6834B only) 1˚ (>100 - 1kHz)
1˚ + 1˚/ kHz
(>1 kHz - 5kHz)
6811B 6812B 6813B 6814B 6834B
Number of phases 1 1 1 1 1/3
Output ratings Power 375 VA 750 VA 1750 VA 3000 VA 4500 VA/1500 VA
rms voltage 300 V 300 V 300 V 300 V (high range) 300 V (high range)
150 V (low range) 150 V (low range)
rms current 3.25 A 6.5 A 13 A
2
10 A (300 V range)
2
15 A/5 A (300 V range)
2
20 A (150 V range)
2
30 A/10 A (150 V range)
Repetitive & non-repetitive 40 A 40 A 80 A 40 A (300 V range) 60 A/20A (300 V range)
peak current 80 A (150 V range)
120 A/40 A (150 V range)
Crest factor 12 6 6 4 4
Load Power factor 0 to 1 0 to 1 0 to 1 0 to 1 0 to 1
capability
dc power 285 W 575 W 1350 W N/A N/A
dc voltage ±425 V ±425 V ±425 V N/A N/A
dc current 2.5 A 5.0 A 10.0 A N/A N/A
Output frequency dc; 45 Hz to dc; 45 Hz to dc; 45 Hz to 45 Hz to 5 kHz 45 Hz to 5 kHz
range 1 kHz 1 kHz 1 kHz
Constant voltage (20 kHz to 10 MHz) -60 dB (relative -60 dB (relative -60 dB (relative -60 dB (relative -60 dB (relative
ripple and noise to full scale) to full scale) to full scale) to full scale) to full scale)
Line regulation (% of full scale) 0.1% 0.1% 0.1% 0.1% 0.1%
Load regulation (% of full scale) 0.5% 0.5% 0.5% 0.5% 0.5%
Maximum total 0.25% at 50/60 Hz 0.25% at 50/60 Hz 0.25% at 50/60 Hz 1% (45-1000 Hz) 1% (45-1000 Hz)
harmonic distortion 1% worst case 1% worst case 1% worst case 1% + 1%/kHz 1% + 1%/kHz