Technical data
For more information in the U.S.A. call
1-800-452-4844
25
dc Floating Voltage: Output terminals can be floated up to ±240 Vdc
from chassis ground
Remote Sensing: Up to half the rated output voltage can be dropped
across each load lead. Add 2 mV to the voltage load regulation
specification for each 1–V change in the negative output lead
caused by a load current change.
Command Processing Time: The average time for the output voltage
to change after getting an GPIB command is 20 ms
Output Programming Response Time (with full resistive load): The rise
and fall time (10% to 90% and 90% to 10%) of the output voltage
is less than 20 ms. The output voltage change settles within 0.1%
of the final value in less than 120 ms.
Down Programming: An active down-programmer sinks approxi-
mately 10% of the rated output current
Calibration Interval: One year
ac Input of System Mainframe
Voltage 100 Vac 120 Vac 200 Vac 220 Vac 230 Vac 240 Vac
Max. Current 29 A 25 A 16 A 16 A 15 A 15 A
Multiple Mainframes at One GPIB Address
The Agilent serial link feature will allow you to control up to 16
outputs at one GPIB address by connecting an auxiliary main-
frame. The serial link cable comes standard with the 66000 MPS
mainframe. For applications with a broader range of power
requirements, one 66000 mainframe can be connected with up
to eight of the 6640, 6650, 6670, 6680, or 6030 series of system
power supplies. This solution provides power ranges from 150
watts to 5,000 watts at one primary GPIB address.
Output Connections
System assembly is simplified thanks to a quick-disconnect
connector assembly on each module. Once your wires are
connected to the load, the connector design permits the mod-
ules to be removed from the front of the mainframe without
disconnecting cabling or removing the mainframe from the
rack. One connector assembly is shipped with each module.
Ordering Information
66000A MPS Mainframe $1,940
*Opt 908
Rack-mount Kit (p/n 5063-9215) +$41
*Opt 909
Rack-mount Kit with Handles +$102
(p/n 5063-9222)
*Note:
Options 908 and 909 require cabinet rails (E3663AC)
or a slide kit (p/n 1494-0059) to support the loaded
mainframe’s weight.
Opt 910 Extra Manual Set (Standard unit is shipped +$36
with Installation Guide only.)
A line cord option must be specified. See pages 48-51.
66001A
MPS Keyboard includes 2m (6 ft) cables $855
66002A
Rack kit for 66001A keyboard
$80
Module Options
66101A
dc Power Module 8 V, 16 A $1,785
66102A
dc Power Module 20 V, 7.5 A $1,785
66103A
dc Power Module 35 V, 4.5 A $1,785
66104A
dc Power Module 60 V, 2.5 A $1,785
66105A
dc Power Module 120 V, 1.25 A $1,785
66106A
dc Power Module 200 V, 0.75 A $1,785
Opt 760
Open/Close and Polarity Reversal Relays +$184
Opt 910
Service Manual, Extra Programming Guide
and Operating Guide
Accessories
p/n 5060-3351 Field-Installable Relay Kit $180
p/n 5060-3386
Standard Connector Assembly $185
p/n 5060-3387
Standard Connector Assembly with $280
installed relays (Option 760)
p/n 66000-90001 Mainframe Installation Guide $10
p/n 5959-3360
dc Power Module User’s Guide $12
p/n 5959-3362
dc Power Module Programming Guide $20
p/n 66000-90003
Mainframe Service Manual $18
p/n 5959-3364
dc Power Module Service Manual $28
p/n 1252-1488
4-Pin FLT/Inhibit Connector $10
E3663AC
Support rails for Agilent rack cabinets
Input Power of System Mainframe: 3200 VA (max.), 1800 W (max.), 1600 W (typ.)
GPIB Capabilities: SH1, AH1, TE6, LE4, SR1, RL1, PP0, DC1, DT1, E1,
and C0, and a command set compatible with IEEE-488.2 and SCPI
Regulatory Compliance: Listed to UL 1244; certified to CSA 22.2
No. 231; conforms to IEC 61010-1.
See page 73 for more
information
Weight:
Net, 66000A, 15 kg (33 lb); 66001A, 1.05 kg (2.3 lb);
66101-66106A, 2.8 kg (6 lb). Shipping, 66000A, 19 kg (42 lb);
66001A, 1.34 kg (2.95 lb); 66101–66106A, 4.1 kg (9 lb).
Size: 66000A: 425.7 mm W x 192 mm H x 677.93 mm D
(16.76 in x 7.28 in x 26.69 in), including feet and rear connectors
(See Page 58 for more details.)
Warranty Period: Three years
Output Sequencing
Increase test throughput by using the output sequencing feature
of the 66000 MPS. This powerful feature allows you to download
up to 20 voltage, current, and dwell-time parameter sets
per output. This sequence can be paced by the programmed
Key Literature
66000 Modular Power System Product Note
p/n 5091-2497E
dwell times. As an alternative, triggers can be used to step through
the output list. The output sequences can be executed without con-
troller intervention, thereby increasing overall test system through-
put. More detailed information on the triggering and output
sequencing capabilities can be obtained by ordering the 66000
Modular Power System Product Note (p/n 5091-2497E) described
below.
A
B
C
D
E
System
dc Power
Supplies