Technical data

6625A
6626A
6628A
6629A
2 or 4 independent isolated outputs
Dual-range linear outputs
Low ripple and noise
Fast up- and down-programming
14-bit programming and readback of voltage and current
Current sourcing and sinking
For more information in the U.S.A. call
1-800-452-4844
dc Floating Voltage: All outputs can be floated up to ±240 Vdc
from chassis ground
Remote Sensing: Up to 10 V drop per load lead. The drop in the load
leads is subtracted from the voltage available for the load.
Command Processing Time: 7 ms typical with front-panel
display disabled
Input Power: 550 W max., 720 VA max.
GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP1, DC1,
DT0, C0, E1.
Regulatory Compliance: Listed to UL 1244; conforms to IEC 61010-1.
See page 73 for more information.
Size: 425.5 mm W x 132.6 mm H x 497.8 mm D
(16.75 in x 5.22 in x 19.6 in) See page 56 for more details
Weight: 6626A, 6629A: Net, 17.4 kg (38 lb); shipping,
22.7 kg (50 lb) 6625A, 6628A: Net, 15.5 kg (34 lb);
shipping, 20.8 kg (46 lb)
STANDARD: 104 to 127 Vac, 47 to 66 Hz, 5.4 A
Opt 100 87 to 106 Vac, 47 to 66 Hz Input, 6.3 A $0
(Japan only)
Opt 220 191 to 233 Vac, 47 to 66 Hz, 3.0 A $0
Opt 240
209 to 250 Vac, 47 to 66 Hz, 3.0 A $0
Opt 750
Relay Control and DFI/RI +$280
*Opt 908
Rack-mount Kit (p/n 5062-3977) +$41
*Opt 909
Rack-mount Kit w/Handles +$92
(p/n 5063-9221)
Opt 910 Service Manual and Extra Operating +$56
Manual
*Support rails required
Ordering Information
25-watt output 50-watt output
Output Power Low-range volts, amps
0 to 7 V, 0 to 15 mA 0 to 16 V, 0 to 200 mA
High range volts, amps
0 to 50 V, 0 to 500 mA 0 to 50 V, 0 to 1 A or
0 to 16 V, 0 to 2 A
Output combinations
for each model (total number of outputs)
6625A (2) Precision 11
6626A (4) Precision 22
6628A (2) Precision —2
6629A (4) Precision —4
Programming accuracy Voltage
1.5 mV + 0.016% (low) 3 mV + 0.016% (low)
(at 25°C ±5°C)
10 mV + 0.016% (high) 10 mV + 0.016% (high)
Current
15 µA + 0.04% (low) 185 µA + 0.04% (low)
100 µA + 0.04% (high) 500 µA + 0.04% (high)
Ripple and noise Constant voltage rms 500 µV 500 µV
(peak-to-peak, 20 Hz to 20 MHz;
rms, 20 Hz to 10 MHz)
peak-to-peak 3 mV 3 mV
Constant current rms 0.1 mA 0.1 mA
Load regulation Voltage 0.5 mV 0.5 mV
Current 0.005 mA 0.01 mA
Load cross regulation Voltage 0.25 mV 0.25 mV
Current 0.005 mA 0.01 mA
Line regulation Voltage 0.5 mV 0.5 mV
Current 0.005 mA 0.01 mA
Transient response time Less than 75 µs for the output to recover to within 75 mV of nominal value following a load
change within specfications
Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product)
25-watt output 50-watt output
Average programming resolution Voltage 460 µV (low) 1 mV (low)
3.2 mV (high) 3.2 mV (high)
Current 1 µA (low) 13 µA (low)
33 µA (high) 131 µA (high)
OVP 230 mV 230 mV
Output Programming response time 6 ms 6 ms
(time to settle within 0.1% of full scale output, after Vset
command has been processed)
(at 0˚ to 55˚ C unless otherwise specified)
SPECIFICATIONS
Warranty Period: Three years
A
B
C
D
E
System
dc Power
Supplies
6625A, 6626A, 6628A, 6629A
ACCESSORIES
p/n 1494-0059
Rack Slide Kit
E3663AC Support rails for
Agilent rack cabinets
AGILENT SYSTEM dc POWER SUPPLIES 21
Precision Measurement
Multiple-Output: 25 W and 50 W