AGILENT SYSTEM dc POWER SUPPLIES 15
Single-Output: 500 W
6651A
6652A
6653A
6654A
6655A
(at 0˚ to 55˚ C unless otherwise specified)
Complete front-panel control, calibration and display
Remote programming and sensing
Fan-speed control to minimize acoustic noise
Low ripple and noise
Over-voltage and over-current protection
Linear output regulation
Fast up-and down-programming
SCPI (Standard Commands for Programmable Instruments)
Serial link connects up to 16 units to one HP-IB address
VXI
plug&play
drivers
6651A 6652A 6653A 6654A 6655A
Output ratings Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V
Output current (40˚ C) 0 to 50 A 0 to 25 A 0 to 15 A 0 to 9 A 0 to 4 A
Maximum current (50˚ C/55˚ C) 45 A/42.5 A 22.5 A/21.3 A 13.5 A/12.8 A 8.1 A/7.7 A 3.6 A/3.4 A
Programming accuracy
Voltage 0.06% + 5 mV 10 mV 15 mV 26 mV 51 mV
at 25˚C ±5˚C Current 0.15% + 60 mA 25 mA 13 mA 8 mA 4 mA
Ripple and noise Voltage rms 300 µV 300 µV 400 µV 500 µV 700 µV
from 20 Hz to 20 MHz peak-peak 3 mV 3 mV 4 mV 5 mV 7 mV
Current rms 25 mA 10 mA 5 mA 3 mA 2 mA
Readback accuracy Voltage 0.07% + 6 mV 15 mV 25 mV 40 mV 80 mV
at 25˚C ±5˚C (percent +Current 0.15% + 67 mA 26 mA 15 mA 7 mA 3 mA
of reading plus fixed) –Current 0.35% + 100 mA 44 mA 24 mA 15 mA 7 mA
System models only
Load regulation Voltage 1 mV 2 mV 3 mV 4 mV 5 mV
Current 2 mA 1 mA 0.5 mA 0.5 mA 0.5 mA
Line regulation Voltage 0.5 mV 0.5 mV 1 mV 1mV 2 mV
Current 2 mA 1 mA 0.75 mA 0.5 mA 0.5 mA
Transient Less than 100
µ
s for the output voltage to recover to its previous level (within 0.1% of the voltage rating
response time of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product)
Average resolution Voltage 2 mV 5 mV 10 mV 15 mV 30 mV
Current 15 mA 7 mA 4 mA 2.5 mA 1.25 mA
OVP 12 mV 30 mV 54 mV 93 mV 190 mV
OVP accuracy 160 mV 400 mV 700 mV 1.2 V 2.4 V
000 000 000 000 000
000 000 000 000 000
dc Floating Voltage: Output terminals can be floated up to ±240 Vdc
from chassis ground
Remote Sensing: Up to half the rated output voltage can be dropped
in each load lead. The drop in the load leads subtracts from the
voltage available for the load.
Command Processing Time: Average time required for the output
voltage to begin to change following receipt of digital data is
20 ms for the power supplies connected directly to the GPIB
Output Programming Response Time: The rise and fall time (10/90% and
90/10%) of the output voltage is less than 15 ms. The output
voltage change settles within 1 LSB (0.025% x rated voltage) of
final value in less than 60 ms.
Down Programming: An active down programmer sinks approximately
20% of the rated output current
Modulation: (Analog programming of output voltage and current)
Input signal: 0 to –5 V
Input impedance: 10 k Ohm nominal
ac Input: (ac input frequency 47 to 63 Hz)
Voltage 100 Vac 120 Vac 220 Vac 240 Vac
Current 12 A 10 A 5.7 A 5.3 A
Input Power: 1,380 VA, 1,100 W at full load; 120 W at no load
GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1,
DT1, E1, and C0. IEEE-488.2 and SCPI-compatible command set.
Regulatory Compliance: Listed to UL 1244; conforms to IEC 61010-1.
See page 73 for more information.
Size: 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.22 in x
19.6 in) See page 55 for more details
Weight: Net, 25 kg (54 lb); shipping, 28 kg (61 lb)
Warranty Period: Three years
ACCESSORIES
p/n 1494-0059 Accessory Slide Kit $0000
p/n 1252-3698
7-pin Analog Plug 0000
p/n 1252-1488
4-pin Digital Plug 0000
p/n 5080-2148
Serial Link 0000
Cable 2 m (6.6 ft)
E3663AC Support rails for Agilent rack cabinets
Ordering Information
STANDARD 104 to 127 Vac, 47 to 63 Hz
Opt 100
87 to 106 Vac, 47 to 63 Hz
$0000
Opt 220
191 to 233 Vac, 47 to 63 Hz
Opt 240 209 to 250 Vac, 47 to 63 Hz
*Opt 908 Rack-mount Kit 0000
(p/n 5062-3977)
*Opt 909 Rack-mount Kit 0000
w/ Handles (p/n 5063-9221)
Opt 910 Service Manual, 00
extra Operating Guide and
Programming Guide
*Support rails required
SPECIFICATIONS
A
B
C
D
E
System
dc Power
Supplies