12 AGILENT SYSTEM dc POWER SUPPLIES
A
B
C
D
E
System
dc Power
Supplies
Precision Measurement
Single-Output: 80 W and 100 W
Precision low current measurement
Low-output noise
High-speed programming
GPIB and RS-232 interface
SCPI (Standard Commands for Programmable Instruments)
VXI
plug&play
drivers
6631B
6632B
6633B
6634B
6631B - 6634B
(at 0˚ to 55˚ C unless otherwise specified)
6631B 6632B 6633B 6634B
Output ratings Voltage/Current 0 to 8 V/0 to 10 A 0 to 20 V/0 to 5 A 0 to 50 V/0 to 2 A 0 to 100 V/0 to 1 A
Programming accuracy
Voltage/+ Current 0.05% + 5 mV/4 mA 10 mV/2 mA 20 mV/1 mA 50 mV/0.5 mA
at 25˚C ±5˚C
Ripple and noise Voltage Normal mode (rms/p-p) 0.3 mV/3 mV 0.3 mV/3 mV 0.5 mV/3 mV 0.5 mV/3 mV
(20 Hz to 20 MHz, with
outputs ungrounded
Fast mode (rms/p-p) 1 mV/10 mV 1 mV/10 mV 1 mV/15 mV 2 mV/25 mV
or with either
terminal grounded) Current (rms) 3 mA 2 mA 2 mA 2 mA
DC measurement Voltage 0.03% + 2 mV 3 mV 6 mV 12 mV
accuracy: via GPIB Low current range
or front panel meters –20 mA to +20 mA 0.1% + 2.5 µA 2.5 µA 2.5 µA 2.5 µA
with respect to actual High current range
output at 25˚C ±5˚C +20 mA to + rated I 0.2% + 1 mA 0.5 mA 0.25 mA 0.25 mA
–20 mA to –rated I 0.2% + 1.6 mA 1.1 mA 0.85 mA 0.85 mA
Load regulation Voltage 2 mV 2 mV 4 mV 5 mV
Current 2 mA 1 mA 1 mA 1 mA
Line regulation Voltage 0.5 mV 0.5 mV 1 mV 1 mV
Current 1 mA 0.5 mA 0.25 mA 0.25 mA
Transient Less than 100 µs (50 µs in the fast mode) for the output voltage to recover to its previous level (within 0.1% of the voltage
response time rating of the supply or 20 mV) following any step change in load current of up to 50% of the output current rating of the supply
Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product)
Average programming
Voltage 2 mV 5 mV 12.5 mV 25 mV
resolution Current 2.5 mA 1.25 mA 0.5 mA 0.25 mA
Sink current 10 A 5 A 2 A 1 A
Sink current tracking SCPI mode 0.4% + 4 mA 0.4% + 2 mA 0.4% + 1 mA 0.4% + 0.5 mA
Compatability mode -500 mA -250 mA -100 mA -50 mA
Minimum current in
40 mA 20 mA 8 mA 4 mA
constant current mode*
SPECIFICATIONS
dc Floating Voltage: Output terminals can be floated up to
±240 Vdc maximum from chassis ground
Remote Sensing: Up to two volts dropped in each load lead. Add 2
mV to the voltage load regulation specification for each one volt
change in the positive output lead due to load current change.
Command-Processing Time:
Average time required for the output
voltage
to begin to change following receipt of digital data is 4
ms for the power supplies connected directly to the GPIB.
(Display disabled.)
Output-Programming Response Time: The rise and fall time (10/90%
and 90/10%) of the output voltage is less than 2 ms (400 µs in
fast mode). The output voltage change settles within 1 LSB
(0.025% x rated voltage) of final value in less than 6 ms
(2 ms in the fast mode).
GPIB Interface Capabilities: IEEE-488.2, SCPI command set and
6630A Series programming compatability
Measurement Time: Average time to make a voltage or current
measurement is 50 ms.
Input Power (full load): 3.5 A, 250 W
Regulatory Compliance: Complies with EMC directive 89/336/EEC
(ISM 1B). See page 73 for more information.
Warranty Period: Three years
* When programming in the 6630A Series language compatibility mode.
Size: 425.5 mm W x 88.1 mm H x 364.4 mm D (16.8 in x 3.5 in x 14.3 in).
See page 57 for more information
Weight: Net, 12.7 kg (28 lb) net; 15.0 kg (33 lb) shipping
STANDARD:104 to 127 Vac, 47 to 63 Hz
Opt 100 87 to 106 Vac, 47 to 63 Hz$0
Opt 220
191 to 233 Vac, 47 to 63 Hz$0
Opt 230
207 to 253 Vac, 47 to 63 Hz$0
Opt 020
Front-panel Binding Posts+$87
Opt 760
Isolation and Reversal Relays
(N/A on 6631B)
+$180
*Opt 1CM
Rack-mount Kit,
p/n 5063-9212+$36
*Opt 1CP
Rack-mount Kit with Handles,
p/n 5063-9219+$82
Opt 910
Service Manual, extra+$36
Operating Guide and
Programming Guide
*
Support rails required
ACCESSORIES
p/n 1494-0060 Rack Slide Kit
E3663AC Support rails for Agilent
rack cabinets
Ordering Information