dc Floating Voltage: Output terminals can be floated up to ±50 Vdc
maximum from chassis ground (±240 volts for 66332A).
Remote Sensing: 66332A, up to 2 V dropped in each load lead.
Add 2 mV to the load regulation specification for each 1 V
change in the positive output lead due to load current change.
For 66309B/D, 66311B/D, up to 4 V can be dropped across
each load lead add 2 mV to the voltage load regulation specifi-
cation for each 1 V change in the positive output lead due to
load current change. For 66319B/D, 66321B/D up to 3 V
total in both load leads on the main output. For auxiliary output
on the 66319B/D, up to 4 V in each load lead.
Command Processing Time: Average time required for the output
voltage to begin to change following receipt of digital data is
4 ms for the power supplies connected directly to the GPIB.
(Display disabled).
Output Programming Response Time: For 66332A the rise and
fall time (10/90% and 90/10%) of the output voltage is:
<2 ms (400 µs for the 66332A in fast mode); for 66311B/D,
66321B/D, Output 1- 66309B/D, 66319B/D: <200 µs.
The output voltage change settles within 1 LSB (0.025% x rated
voltage) of final value for 66332A in: <6ms (2 ms in fast mode);
66309B/D, 66311B/D: 2 ms.
Measurement Time: Average time to process query, calculate
measurement parameter and return data is 50 ms (includes
the default time of 30 ms for acquiring data, and a 20 ms data
processing overhead.)
GPIB Interface Capabilities: IEEE-488.2, SCPI command set, and
6630A series programming capability (except 66309B/D,
66319B/D, 66321B/D).
Input (full load): 47-63 Hz @ 100 Vac mains: 66311B/D,
66321B/D: 1.7 A, 125 W; 66309B/D, 66319B/D: 2 A,
170 W; 66332A: 3.5 A, 250 W.
Regulatory Compliance: Complies with EMC directive 89/336/EEC
(ISM 1B). See page 73 for more information.
Warranty Period: 3 years.
Size: 66309B/D, 66311B/D, 66319B/D,
66321B/D: 212.8 mm W x 88.1 mm H x 435 mm D
(8.4 in x 3.5 in x 17.13 in). 66332A: 425.5 mm
W x 88.1 mm H x 364.4 mm D (16.8 in x 3.5 in x 14.3 in).
See page 56 for more details
Weight: 66309B/D, 66311B/D, 66319B/D, 66321B/D:
9.07 kg (20 lb) net, 11.1 kg (24.5 lb) shipping.
66332A: 12.7 kg (28 lb) net, 15.0 kg (33 lb) shipping.
Ordering Information
Standard: 104 to 127 Vac 47 to 63 Hz
Opt 100 87 to 106 Vac, 47 to 63 Hz
Opt 220 191 to 233 Vac, 47 to 63 Hz
Opt 230 207 to 253 Vac, 47 to 63 Hz
Opt 020 Front-panel Binding Posts (66332A only)
Opt 521 Solid State Relays (66309B/D, 66319B/D)
Opt 760 Isolation and Reversal Relays (66332A only)
*Opt 1CM Rack-mount Kit 66309B/D, 66311B/D,
66319B/D, 66321B/D: p/n 5063-9240
66332A: p/n 5063-9212
*Opt 1CP Rack-mount Kit with Handles, p/n 5063-9219
(66332A only)
A
B
C
D
E
System
dc Power
Supplies
66321B/D, 66319B/D
AGILENT SYSTEM dc POWER SUPPLIES 11
Mobile Communications dc sources-40 W to 100 W
3
3
Agilent 66321B/D, 66319B/D Mobile Communications
dc Source w/Battery Emulation
These four new high performance models offer wireless
electronic device manufacturers, designers, and repairers all
the capabilities to thoroughly test wireless phones and
portable devices.
Performs like a battery
With its battery emulation feature, the Agilent 66321B/D and
66319B/D allows you to test your phones under the same
power conditions as in actual use; detecting early product fail-
ures. These power supplies simulates the effects of the internal
resistance in a battery, enabling them to emulate the operation
of various battery types, as well as batteries in different charged
states.Plus with their ability to simulate negative resistance,
users can compensate for the voltage drop due to the wiring
in a fixture.
Minimize test interruptions
Offering superior transient performance, unmatched in the
market place, the Agilent Mobile Communications dc Sources
w/Battery Emulation dramatically reduces the transient voltage
drop (<40µs) due to the pulse loading characteristics of mobile
phones and recovers very quickly to their original voltage. The
Agilent 66321B/D and 66319B/D enables you to maximize
test throughput by minimizing test interruption due to triggering
of low voltage phone shutdown.
Dynamic Measurement Capability
For WCDMA, CDMA, TDMA, GSM, PCS, DECT, TETRA,
PHS, NADC and other format phone, the advanced measure-
ment subsystem of these power sources, allows you to rapidly
perform peak and low-level current measurements with a high
degree of accuracy.
Simplify test & analysis
With the Agilent 14565A Device Characterization Software
testing, analyzing, and, troubleshooting mobile phone design
and subsystem is made simple. The optional Agilent 14565A
graphical user interface lets you easily control these power sup-
plies. Plus it provides an oscilloscope-like view of the voltage or
current waveform of the device under test, provides reference
waveform save/recall, and oscilloscope-like waveform measure-
ment and analysis (current or voltage measurements, triggering,
markers, zoom control, and more).
*Opt AXS Rack-mount Kit for side-by-side mounting,
(N/A for 66332A) Locking Kit p/n 5061-9694;
Flange Kit p/n 5063-9212
Opt OBN Service Manual, extra User’s Guide and
Programming Guide
* Support rails required
Accessories
p/n 1494-0060 Rack Slide Kit (66332A only)
E3663AC Support rails for Agilent rack cabinets