Technical data
Visit our web site
http://www.agilent.com/find/power
66309B/D
66311B/D
66319B/D
66321B/D
66332A
Ideal for wireless/portable product test
Programmable output reisistance (66319B/D and 66321B/D only)
Dynamic pulse measurement
High-speed programming
SCPI (Standard Commands for Programmable Instruments)
GPIB interface
1
, VXI
plug&play
drivers
Notes:
1
66332A also has RS-232 interface.
2
Applies with current detector set to dc.
3
Time for the output voltage to recover to within 20 mV of final value after 0.1 to 1.5 A load change in high capacitance compensation range.
4
Time for the output voltage to recover to within 20 mV or 0.1% of the voltage rating of the unit following a change in load current of up to 50% of the output current rating.
System
dc Power
Supplies
66309B/D, 66311B/D
10 AGILENT SYSTEM dc POWER SUPPLIES
Mobile Communications dc sources-40 W to 100 W
A
B
C
D
E
(at 0˚ to 55˚ C unless otherwise specified)
SPECIFICATIONS
3
3
Agilent Mobile Communications dc Sources
Model 66309B/D 66311B/D 66319B/D 66321B/D 66332A
Number of outputs 21211
Output ratings Voltage 0 to 15V 0 to 15V 0 to 15V 0 to 15V 0 to 20V
Current 0 to 3A 0 to 3A 0 to 3A 0 to 3A 0 to 5A
Peak current for up to 7 ms 5 A 5 A 5 A 5 A 5 A
Programming accuracy Voltage 0.05%+ 10 mV 10 mV 10 mV 10 mV 10 mV
at 25˚C ±5˚C (% of setting plus fixed)
+Current 0.05%+ 1.33 mA 1.33 mA 1.33 mA 1.33 mA 2 mA
Ripple and Noise Voltage(rms/p-p) 1 mV/6 mV 1 mV/6 mV 1 mV/6 mV 1 mV/6 mV 0.3 mV/3 mV
(20Hz to 20 MHz)
Current (rms) 2 mA 2 mA 2 mA 2 mA 2 mA
dc measurement accuracy Voltage 0.03%+ 5 mV 5 mV 5 mV 5 mV 3 mV
+20 mA to + rated current 0.2%+
0.5 mA
2
0.5 mA
2
0.5 mA
-20 mA to - rated current 0.2%+
1.1 mA 1.1 mA 1.1 mA
-3A to + 5A 0.2% 0.5 mA
2
0.5 mA
2
-1A to + 1A 0.1% 0.2 mA 0.2 mA
-20 mA to + 2.5 µA 2.5 µA 2.5 µA 2.5 µA 2.5 µA
20 mA range 0.1%+
Dynamic measurement system Buffer size 4096 points 4096 points 4096 points 4096 points 4096 points
Sampling interval 15 µs - 31,200 s 15 µs - 31,200 s 15 µs - 31,200 s 15 µs - 31,200 s 15 µs - 31,200 s
Transient response time <35 µs
3
<35 µs
3
<20 µs
3
<20 µs <100 µs
4
Transient voltage dip 70 mV 70 mV 40 mV 40 mV 500 mV
(typical with up to 15 feet 22 AWG wiring)
Programmable output resistance Range -40 m
Ω to
+1
Ω
-40 m
Ω
to +1
Ω
Programming accuracy 0.5% + 2 m
Ω
0.5% + 2 m
Ω
Resolution 1 m
Ω
1 m
Ω
Voltmeter input -25 to +25 Vdc -25 to +25 Vdc -25 to +25 Vdc -25 to +25 Vdc N/A
(66309D, 66319D, 66311D and 66321D only)
Input range
dc readback accuracy 0.04% +5 mV 0.04% +5 mV 0.04% +5 mV 0.04% +5 mV
(at 25˚C ±5˚C)
ac + dc readback accuracy 1% + 5 mV 1% + 5 mV 1% + 5 mV 1% + 5 mV
(at 25˚C ±5˚C) with dc plus (60 Hz to 10 kHz) (60 Hz to 10 kHz) (60 Hz to 10 kHz) (60 Hz to 10 kHz)
a sinewave input > 25 mV rms
Auxilary output (66309B/D and 66319B/D) N/A N/A N/A
Output ratings Voltage 0 to 12V 0 to 12V
Current 0 to 1.5 A 0 to 1.5 A
Programming accuracy Voltage 0.2% + 40 mV 0.2% + 40 mV
+Current 0.2% + 4.5 mA 0.2% + 4.5 mA
dc measurement accuracy Voltage 0.2% + 15 mV 0.2% + 15 mV
+Current 0.2% + 3 mA 0.2% + 3 mA
Ripple and Noise Voltage(rms/p-p) 1 mV/6 mV 1 mV/6 mV
(20Hz to 20 MHz) Current (rms) 2 mA 2 mA