Technical data
6611C
6612C
6613C
6614C
System
dc Power
Supplies
For more information in the U.S.A. call
1-800-452-4844
AGILENT SYSTEM dc POWER SUPPLIES
9
Precision Measurement,
Single-Output: 40 W and 50 W
Precision low current measurement
Low output noise
High speed programming
GPIB and RS-232 interface
SCPI (Standard Commands for programmable instruments)
VXI
plug&play
drivers
A
B
C
D
E
6611C - 6614C
dc Floating Voltage: Output terminals can be floated up to ±240 Vdc
maximum from chassis ground
Remote Sensing: Up to two volts dropped in each load lead. Add 2
mV to the voltage load regulation specification for each one volt
change in the postive output lead due to load current change.
Command Processing Time: Average time required for the output
voltage to begin to change following receipt of digital date is
4 ms for the power supplies connected directly to the GPIB.
Output Programming Response Time: The rise and fall time (10/90%
and 90/10%) of the output voltage is less than 2 ms. The output
voltage change settles within 1 LSB (0.025% x rated voltage)
of final value in less than 6 ms.
GPIB Interface Capabilities: IEEE-488.2, SCPI command set, and
6630A Series programming compatability
Input Power: (full load): 1.6 A, 100 W (6611C: 2.2 A, 120 W)
Regulatory Compliance: Complies with EMC directive 89/336/EEC
(ISM 1B). See page 73 for more information.
Warranty Period: Three years
Size: 212.8 mm W x 88.1 mm H x 368.3 mm D
(8.4 in x 3.5 in x 14.5 in)
See page 56 for more details
Weight: 8.2 kg (18.16 lb) net; 10.6 kg (23.5 lb) shipping
STANDARD: 104 to 127 Vac, 47 to 63 Hz
Opt 100 87 to 106 Vac, 47 to 63 Hz $0
Opt 220
191 to 233 Vac, 47 to 63 Hz $0
Opt 230
207 to 253 Vac, 47 to 63 Hz $0
Opt 760
Isolation and Reversal relays +$184
*Opt ICM
Rack-mount Kit (p/n 5063-9240) +$61
*Opt AXS
Rack-mount Kit side-by-side +$92
mounting of two units, Lock-link Kit
p/n 5061-9694; Flange Kit p/n 5062-3974
Opt OBN Service Manual, Extra Operating Guide +$56
and Programming Guide only.
*Support rails required
ACCESSORIES
Rack-mount and slide for two side-by-side units of
different lengths p/n 1494-0015,
5063-9255 and filler panel 5002-3999
Rack-mount slide and support for one instrument
p/n 1494-0015, 5063-9255 and filler panel 5002-3999
E3663AC Support rails for Agilent rack cabinets
Ordering Information
(at 0˚ to 55˚ C unless otherwise specified)
Single Output System
6611C 6612C 6613C 6614C
Output Ratings Voltage/Current
0 to 8 V/0 to 5 A 0 to 20 V/0 to 2 A 0 to 50 V, 0 to 1 A 0 to 100 V/0 to 0.5 A
Programming accuracy Voltage/+Current 0.05% +
5 m V/2 m A 10 m V/1 m A 20 m V/0.75 m A 50 m V/0.5 m A
(at 25˚C ±5˚C)
Ripple and noise Voltage Normal mode
20 Hz to 20 MHz, with outputs ungrounded rms/p-p 0.5 mV/3 mV 0.5 mV/3 mV 0.5 mV/4 mV 0.5 mV/5 mV
or with either terminal grounded
rms 2 mA 1 mA 1 mA 1 mA
dc measurement accuracy Voltage 0.03% + 2 mV 3 mV 6 mV 12 mV
via GPIB or front-panel meters Low current range
respect to actual output at 25˚C ±5˚C -20 mA to + 20 mA 0.1% + 2.5 µA 2.5 µA 2.5 µA 2.5 µA
High current range
+20 mA to + rated 1 0.2% + 0.5 mA 0.25 mA 0.2 mA 0.1 mA
-20 mA to - rated 1 0.2% + 1.1 mA 0.85 mA 0.8 mA 0.7 mA
Load regulation Voltage/Current 2 mV/1 mA 2 mV/0.5 mA 4 mV/0.5 mA 5 mV/0.5 mA
Line regulation Voltage/Current 0.5 mV/ 0.5 mA 0.5 mV/0.5 mA 1 mV/0.25 mA 1 mV/0.25 mA
Transient response time Less than 100 µs for the output to recover to its previous level (within 0.1% of the voltage rating of the supply
or 20 mV, whichever is greater) following any step change in load current of up to 50% of the output current
rating of the supply
Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product)
Average programming resolution Voltage/Current 2 mV/1.25 mA 5 mV/0.5 mA 12.5 mV/0.25 mA 25 mV/0.125 mA
Sink current 3 A 1.2 A 0.6 A 0.3 A
SPECIFICATIONS