Technical data
Visit our web site
http://www.agilent.com/find/power
8 AGILENT SYSTEM dc POWER SUPPLIES
A
B
C
D
E
System
dc Power
Supplies
Single-Output: 30 W to 80 W
Single-Output, Dual-Range
Low noise/excellent line and load regulation
GPIB/RS-232 standard
SCPI (Standard Commands for Programmable Instrument) compatible
Front and rear output terminals
Overvoltage protection
Remote sense at rear output
Agilent E3640A – 45A Single Output
The new E3640A-series programmable dc power supplies are
30W/50W/80W single output dc power supplies with standard
GPIB & RS-232 interface. For general-purpose use, these pro-
grammable power supplies offer the performance of system
power supplies at a surprisingly affordable price.
Clean and Stable Output
All models deliver clean and reliable power, dependable regu-
lation (0.01%) and fast transient response (<50usec to within
15mV). With 0.01% load and line regulation, Agilent E364xA
power supplies keep output steady when power line and load
changes occur. These linear supplies specify both normal
mode voltage noise and common mode current noise to
assure less interference with your DUT.
Standard remote interface
Standard GPIB and RS-232 interfaces, SCPI programming and
plug&play drivers for Agilent VEE and NI LabView make it
easy to program and integrate into automated test systems.
You can monitor the output terminals for voltage and current,
and a query command lets you read the programmed voltage
and current.
Versatile Power
Agilent E364xA power supplies give you the flexibility to select
from dual output ranges. Both front and rear output terminals
are standard and output load is protected against over-voltage
protection function. Remote sense is available to eliminate the
errors due to voltage drops on the load leads. New front panel
binding posts offer flexibility to use safety test leads, banana
plugs or stripped wires. Store and recall key enables you to save
and recall up to 5 frequently used operating states.
(at 0˚ to 55˚ C unless otherwise specified)
Ordering Information
STANDARD: 115 Vac +/- 10%, 47 to 63 Hz
Opt 0E3 230 Vac +/- 10%, 47 to 63 Hz
Opt 0E9 100 Vac +/- 10%, 47 to 63 Hz
Opt 1CM Rackmount Kit (p/n 5063-9240)
Opt 910 Extra Manual set
A
CCESSORIES
E3619A 18 AWG power supply test leads
E3640A, E3641A, E3642A, E3643A,
E3644A, E3645A
E3640A
E3641A
E3642A
E3643A
E3644A
E3645A
Temperature coefficient: <0.01% + 3 mV, <0.02% + 3 mA change per
degree C over operating range 0-40 degree C after 30 minute warm-up
Warranty: Three years
Size: 254.4 mm W x 104 mm H x 374 mm D (10 in. x 4.1 in. x 14.8 in.)
Weight: E3640A, E3641A: 5.3 kg (11.7 lbs)
E3642A, E3643A: 6.2 kg (13.7 lbs)
E3644A, E3645A: 6 kg (13.2 lbs)
dc Floating Voltage: Output terminals can be floated up to
±240Vdc from chassis ground.
Remote Sensing: Up to 1V can be dropped in each load
lead. The drop in the load leads subtracts from the
voltage available for the load.
Settling Time: Less than 90msec for the output voltage to
change from 1% to 99% or vice versa following the
receipt of VOLTage or APPLy command via direct
GPIB or RS-232 interface.
Product Regulation:
Designed to comply with UL3111-1; certi-
fied to CSA 22.2 No. 1010.1; conforms to IEC 1010-1;
complies with EMC directive 89/336/EEC(Group1, Class A)
OVP accuracy: 0.5% + 0.5 V, activation time:
≥
3 V,
<1.5 ms, and <3 V, <10 ms
Isolation: +/- 240 Vdc
Stability: Voltage <0.02% + 2 mV; Current <0.1% + 1 mA
SPECIFICATIONS
Agilent Model
E3640A E3641A E3642A E3643A E3644A E3645A
Number of Outputs 1 1 1 1 1 1
dc outputs
Voltage/Current 0 to 8 V/3 A 0 to 35 V/0.8 A 0 to 8 V/5 A 0 to 35 V/1.4 A 0 to 8 V/8 A 0 to 35 V/2.2 A
0 to 20 V/1.5 A 0 to 60 V/0.5 A 0 to 20 V/2.5 A 0 to 60 V/0.8 A 0 to 20 V/4 A 0 to 60 V/1.3 A
Power (max)
30 W 30 W 50 W 50 W 80 W 80 W
Load and line regulation
Voltage/Current <0.01% + 3 mV <0.01% + 3 mV <0.01% + 3 mV <0.01% + 3 mV <0.01% + 3 mV <0.01% + 3 mV
<0.01% + 250 µA <0.01% + 250 µA <0.01% + 250 µA <0.01% + 250 µA <0.01% + 250 µA <0.01% + 250 µA
Ripple and noise
Normal-Mode Voltage <500 µVrms/5 mVp-p <1 mVrms/8 mVp-p <500 µVrms/5 mVp-p <1 mVrms/8 mVp-p <500 µVrms/5 mVp-p <1 mVrms/8 mVp-p
(20 Hz to 20 MHz) Normal-Mode Current <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms
Common-Mode Current <1.5 µArms <1.5 µArms <1.5 µArms <1.5 µArms <1.5 µArms <1.5 µArms
Programming accuracy
Voltage <0.05% +10 mV <0.05% +10 mV <0.05% +10 mV <0.05% +10 mV <0.05% +10 mV <0.05% +10 mV
(at 25˚ C ± 5˚ C) Current <0.2% +10 mA <0.2% +10 mA <0.2% +10 mA <0.2% +10 mA <0.2% +10 mA <0.2% +10 mA
Readback accuracy
Voltage <0.05% + 5 mV <0.05% + 5 mV <0.05% + 5 mV <0.05% + 5 mV <0.05% + 5 mV <0.05% + 5 mV
(at 25˚ C ± 5˚ C) Current <0.15% + 5 mA <0.15% + 5 mA <0.15% + 5 mA <0.15% + 5 mA <0.15% + 5 mA <0.15% + 5 mA
Program resolution
Voltage/Current 5 mV/1 mA 5 mV/1 mA 5 mV/1 mA 5 mV/1 mA 5 mV/ 1 mA 5 mV/ 1 mA
Readback resolution Voltage/Current 2 mV/1 mA 2 mV/1 mA 2 mV/1 mA 2 mV/1 mA 2 mV/ 1 mA 2 mV/ 1 mA
Meter resolution Voltage/Current 10 mV/1 mA 10 mV/1 mA 10 mV/1 mA 10 mV/1 mA 10 mV/ 1 mA 10 mV/ 1 mA
Transient response time
<50 µs for output to recover within 15 mV following a change in output current from full load to half load or vice versa.