Specifications

81
Supplemental Characteristics
for all model numbers
DC Floating Voltage: Output terminals can
be floated up to ±240 Vdc from chassis
ground
Remote Sensing: Up to half the rated out-
put voltage can be dropped across each
load lead. Add 2 mV to the voltage load
regulation specification for each 1–V
change in the negative output lead
caused by a load current change.
Command Processing Time: The average
time for the output voltage to change
after getting an GPIB command is 20 ms
Output Programming Response Time
(with full resistive load): The rise
and fall time (10% to 90% and 90% to 10%)
of the output voltage is less than 20 ms.
The output voltage change settles within
0.1% of the final value in less than 120 ms.
Down Programming: An active down-
programmer sinks approximately 10%
of the rated output current
Calibration Interval: One year
AC Input of System Mainframe
Voltage 100 Vac 120 Vac 200 Vac 220 Vac 230 Vac 240 Vac
Max. 29 A 25 A 16 A 16 A 15 A 15 A
Current
Input Power of System Mainframe: 3200 VA
(max.), 1800 W (max.), 1600 W (typ.)
GPIB Capabilities: SH1, AH1, TE6, LE4,
SR1, RL1, PP0, DC1, DT1, E1, and C0,
and a command set compatible with
IEEE-488.2 and SCPI
Software Driver:
VXIPlug&Play
Regulatory Compliance: Listed to UL 1244;
certified to CSA 22.2 No. 231; conforms
to IEC 61010-1.
Weight: Net, 66000A, 15 kg (33 lb);
66001A, 1.05 kg (2.3 lb); 66101-66106A,
2.8 kg (6 lb). Shipping, 66000A,
19 kg (42 lb); 66001A, 1.34 kg (2.95 lb);
66101–66106A, 4.1 kg (9 lb).
Size: 66000A: 425.7 mm W x 192 mm H x
677.93 mm D (16.76 in x 7.28 in x 26.69 in),
including feet and rear connectors
Warranty Period: One year
Modular Power System
1200 W per mainframe GPIB (Continued)
Specifications
(at 0
˚
to 55
˚
C unless
otherwise specified)
66103A- 66103A- 66104A- 66105A-
J09 J12 J09 J01
Special Order Special Order Special Order Special Order
Option Option Option Option
Output ratings at 40
˚
C
Output voltage 28.5 V 24 V 55 V 35 V
Output current 5.5 A 6 A 3 A 1.25 A
Maximum power 157 W 144 W 165 W 44 W
Programming accuracy
at 25
˚
C ±5
˚
C
Voltage 0.03% + 13 mV 13 mV 25 mV 15 mV
Current 0.03% + 3 mA 3 mA 1.5 mA 0.6 mA
Readback accuracy
(via GPIB or keyboard
display at 25˚C ±5˚C)
Voltage 0.02% + 8 mV 8 mV 15 mV 9 mV
Current 0.02% + 3 mA 3 mA 1.2 mA 0.6 mA
Ripple and noise (20 Hz to 20 MHz)
Constant Voltage rms 5 mV 5 mV 9 mV 6 mV
peak-peak 10 mV 10 mV 15 mV 11.5 mV
Constant Current rms 4 mA 4 mA 1.2 mA 1 mA
Line regulation
Voltage 1 mV 1 mV 2 mV 1 mV
Current 0.3 mA 0.3 mA 0.1 mA 50 µA
Load regulation
Voltage 1 mV 1 mV 2 mV 1 mV
Current 0.2 mA 0.2 mA 0.1 mA 50 µA
Transient response time Less than 1 ms for the output voltage to recover within 100 mV of its
previous level following any step change in load current up to 10 percent
of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design
that are useful in applying the product)
Average resolution
Voltage 10.4 mV 8 mV 16.5 mV 2 mV
Current 2 mA 2 mA 0.9 mA 1.2 mA
OVP 200 mV 150 mV 350 mV 230 mV
OVP accuracy 800 mV 600 mV 950 mV 920 mV
More detailed specifications at
www.agilent.com/find/66000
High Performance DC Power Supplies speed and accuracy for test optimization