Specifications

26
Supplemental Characteristics
for all model numbers
Remote Sensing: Up to 2 V drop in each
lead. Voltage regulation specification met
with up to 0.5 V drop, but degrades for
greater drops.
Modulation: (analog programming of
output voltage and current)
Input signal: 0 to 5 V or 0 to 4 k Ohms
Regulatory Compliance: Certified to
CSA556B; conforms to IEC 61010-1.
Size:
425.5 mm W x 132.6 mm H x 516.4 mm D
(16.75 in x 5.25 in x 20.33 in).
Warranty: One year
Single-Output, Autoranging
200 W and 1000 W
(Continued)
More detailed specifications at
www.agilent.com/find/6010
Basic DC Power Supplies essential features for a tight budget
Ordering Information
Opt 120 104 to 127 Vac, 47 to 63 Hz
Opt 220 191 to 233 Vac, 48 to 63 Hz
Opt 240 209 to 250 Vac, 48 to 63 Hz
* Opt 908 Rack-mount Kit (p/n 5062-3977)
* Opt 909 Rack-mount Kit with Handles.
(p/n 5062-3983)
Opt 0L1 Full documentation on
CD-ROM, and printed standard
documentation package
Opt 0L2 Extra copy of standard
printed documentation package
Opt 0B0 Full documentation on
CD-ROM only
Opt J01
Stabilization for loads up to 10 Henries
A line cord option must be specified,
see the AC line voltage and cord section.
*Support rails required
Accessories
1494-0060 Rack Slide Kit
E3663AC Support rails for
Agilent rack cabinets
Size
0.6
128mm
5.04"
12.7mm
0.5"
425mm
16.75"
132.6mm
5.2"
12.7mm
0.5"
421.6mm
16.6"
77mm
3.03"
2.5mm
0.1"
Rear
Side
To p
Terminal Strip Detail
Screw Size
M3.5 x 0.6
VM
IM
M
VP
IP
P
B6
B1
+S
-S
Agilent Models: 6010A, 6011A, 6012B, 6015A