User`s guide
Table Of Contents
- Title Page
- Contents
- Getting Started
- Introduction and Measurement
- Phase Noise Basics
- Expanding Your Measurement Experience
- Starting the Measurement Software
- Using the Asset Manager
- Using the Server Hardware Connections to Specify the Source
- Setting GPIB Addresses
- Testing the 8663A Internal/External 10 MHz
- Testing the 8644B Internal/External 10 MHz
- Viewing Markers
- Omitting Spurs
- Displaying the Parameter Summary
- Exporting Measurement Results
- Absolute Measurement Fundamentals
- Absolute Measurement Examples
- Residual Measurement Fundamentals
- What is Residual Noise?
- Assumptions about Residual Phase Noise Measurements
- Calibrating the Measurement
- Measurement Difficulties
- Residual Measurement Examples
- FM Discriminator Fundamentals
- FM Discriminator Measurement Examples
- AM Noise Measurement Fundamentals
- AM Noise Measurement Examples
- Baseband Noise Measurement Examples
- Evaluating Your Measurement Results
- Advanced Software Features
- Reference Graphs and Tables
- Approximate System Noise Floor vs. R Port Signal Level
- Phase Noise Floor and Region of Validity
- Phase Noise Level of Various Agilent Sources
- Increase in Measured Noise as Ref Source Approaches DUT Noise
- Approximate Sensitivity of Delay Line Discriminator
- AM Calibration
- Voltage Controlled Source Tuning Requirements
- Tune Range of VCO for Center Voltage
- Peak Tuning Range Required by Noise Level
- Phase Lock Loop Bandwidth vs. Peak Tuning Range
- Noise Floor Limits Due to Peak Tuning Range
- Tuning Characteristics of Various VCO Source Options
- 8643A Frequency Limits
- 8644B Frequency Limits
- 8664A Frequency Limits
- 8665A Frequency Limits
- 8665B Frequency Limits
- System Specifications
- System Interconnections
- PC Components Installation
- Overview
- Step 1: Uninstall the current version of Agilent Technologies IO libraries
- Step 2: Uninstall all National Instruments products.
- Step 3: Install the National Instruments VXI software.
- Step 4: Install the National Instruments VISA runtime.
- Step 5: Install software for the NI Data Acquisition Software.
- Step 6: Hardware Installation
- Step 7. Finalize National Instruments Software Installation.
- Step 8: System Interconnections
- Step 9: Install Microsoft Visual C++ 2008 Redistributable Package use default settings
- Step 10: Install the Agilent I/O Libraries
- Step 11: Install the E5500 Phase Noise Measurement software.
- Step 12: Asset Configuration
- Step 13: License Key for the Phase Noise Test Set
- Overview
- PC Digitizer Performance Verification
- Preventive Maintenance
- Service, Support, and Safety Information
- Safety and Regulatory Information
- Safety summary
- Equipment Installation
- Environmental conditions
- Before applying power
- Ground the instrument or system
- Fuses and Circuit Breakers
- Maintenance
- Safety symbols and instrument markings
- Regulatory Compliance
- Declaration of Conformity
- Compliance with German noise requirements
- Compliance with Canadian EMC requirements
- Service and Support
- Return Procedure
- Safety and Regulatory Information

398 Agilent E5505A User’s Guide
18
System Interconnections
System Cables
Table 72 shows the E5505A system cables and their connections. Some cables are used only with
specific system options; you may not receive all cables in the table. An additional GPIB cable is
shipped with each optional instrument ordered.
Table 72 E5505A cables and connections
Part Number Description Qty From To
8120-2582 BNC (male) to BNC (male), coaxial, 4 feet 3 Varies with configuration and function
8120-5370 BNC (male) to BNC (male), coaxial, 8 feet 2 Varies with configuration and function
8120-3445 GPIB, 10834A, 1 meter 1 Test set rear panel GPIB Downconverter rear panel GPIB
8120-3446 GPIB, 10834B, 2 meter 1 PC rear panel GPIB Test set rear panel GPIB
E5505-80001 RF, SMA (male) to BNC (male), yellow 1 PC digitizer card adapter IN Test set front panel ANALYZER
<100 MHz OUT
E5505-80002 RF, SMA (male) to BNC (male), green 1 PC digitizer card adapter OUT Test set rear panel CHIRP SOURCE IN
For Test Set, Opt 001
E5505-20001 RF, semi-rigid, N-Type (male) to N-Type
(male)
1 Test set front panel FROM
DOWNCONVERTER
Downconverter front panel IF OUTPUT
E5505-20002 RF, semi-rigid, N-Type (male) to SMA (male) 1 Test set front panel TO
DOWNCONVERTER
N5501A/2A Downconverter front panel
SIGNAL
E5505-20003 RF, semi-rigid, SMA (male) to SMA (male) 1 Test set front panel TO
DOWNCONVERTER
N5507A Downconverter front panel SIGNAL