User`s guide
Table Of Contents
- Title Page
- Contents
- Getting Started
- Introduction and Measurement
- Phase Noise Basics
- Expanding Your Measurement Experience
- Starting the Measurement Software
- Using the Asset Manager
- Using the Server Hardware Connections to Specify the Source
- Setting GPIB Addresses
- Testing the 8663A Internal/External 10 MHz
- Testing the 8644B Internal/External 10 MHz
- Viewing Markers
- Omitting Spurs
- Displaying the Parameter Summary
- Exporting Measurement Results
- Absolute Measurement Fundamentals
- Absolute Measurement Examples
- Residual Measurement Fundamentals
- What is Residual Noise?
- Assumptions about Residual Phase Noise Measurements
- Calibrating the Measurement
- Measurement Difficulties
- Residual Measurement Examples
- FM Discriminator Fundamentals
- FM Discriminator Measurement Examples
- AM Noise Measurement Fundamentals
- AM Noise Measurement Examples
- Baseband Noise Measurement Examples
- Evaluating Your Measurement Results
- Advanced Software Features
- Reference Graphs and Tables
- Approximate System Noise Floor vs. R Port Signal Level
- Phase Noise Floor and Region of Validity
- Phase Noise Level of Various Agilent Sources
- Increase in Measured Noise as Ref Source Approaches DUT Noise
- Approximate Sensitivity of Delay Line Discriminator
- AM Calibration
- Voltage Controlled Source Tuning Requirements
- Tune Range of VCO for Center Voltage
- Peak Tuning Range Required by Noise Level
- Phase Lock Loop Bandwidth vs. Peak Tuning Range
- Noise Floor Limits Due to Peak Tuning Range
- Tuning Characteristics of Various VCO Source Options
- 8643A Frequency Limits
- 8644B Frequency Limits
- 8664A Frequency Limits
- 8665A Frequency Limits
- 8665B Frequency Limits
- System Specifications
- System Interconnections
- PC Components Installation
- Overview
- Step 1: Uninstall the current version of Agilent Technologies IO libraries
- Step 2: Uninstall all National Instruments products.
- Step 3: Install the National Instruments VXI software.
- Step 4: Install the National Instruments VISA runtime.
- Step 5: Install software for the NI Data Acquisition Software.
- Step 6: Hardware Installation
- Step 7. Finalize National Instruments Software Installation.
- Step 8: System Interconnections
- Step 9: Install Microsoft Visual C++ 2008 Redistributable Package use default settings
- Step 10: Install the Agilent I/O Libraries
- Step 11: Install the E5500 Phase Noise Measurement software.
- Step 12: Asset Configuration
- Step 13: License Key for the Phase Noise Test Set
- Overview
- PC Digitizer Performance Verification
- Preventive Maintenance
- Service, Support, and Safety Information
- Safety and Regulatory Information
- Safety summary
- Equipment Installation
- Environmental conditions
- Before applying power
- Ground the instrument or system
- Fuses and Circuit Breakers
- Maintenance
- Safety symbols and instrument markings
- Regulatory Compliance
- Declaration of Conformity
- Compliance with German noise requirements
- Compliance with Canadian EMC requirements
- Service and Support
- Return Procedure
- Safety and Regulatory Information

374 Agilent E5505A User’s Guide
16
Reference Graphs and Tables
8643A Frequency Limits
8643A mode keys
• The [Mode 1] key provides the maximum FM deviation and minimum RF
output switching time. Noise level is highest in this mode, as shown in
Table 57 on page 375.
• The [Mode 2] key provides a median range of FM deviation and RF output
switching time, as shown in Table 57 on page 375. The 8643A defaults to
Mode 2 operation.
Table 56 8643A frequency limits
Note: Special Function 120 must be enabled for DCFM Minimum Recommended PTR (Peak Tune Range)
PTR =FM Deviation x VTR
1
1 Takes into account limited tuning resolution available in linear FM (Special Function 120, refer to “How to access special functions" on
page 375.
Model
Number
Option Band Minimum
(MHz)
Band Maximum (MHz) Mode 2
2
2
T
he 8643A defaults to Mode 2 operation.
Mode 1
3
3 Wideband FM: Use Special Function 125 (refer to “How to access special functions" on page 375.
8643A 002 1030 2060 2000000 20000000
8643A 002 515 1029.99999999 1000000 10000000
8643A Standard 515 1030 1000000 10000000
8643A Both 257.5 514.99999999 500000 5000000
8643A Both 128.75 257.49999999 250000 2500000
8643A Both 64.375 128.74999999 125000 1250000
8643A Both 32.1875 64.37499999 62500 625000
8643A Both 16.09375 32.18749999 31200 312000
8643A Both 8.046875 16.09374999 15600 156000
8643A Both 4.0234375 8.04687499 7810 78100
8643A Both 2.01171875 4.02343749 3900 39000
8643A Both 1.005859375 2.01171874 1950 19500
8643A Both 0.5029296875 1.005859365 976 9760
8643A Both 0.25146484375 0.5029296775 488 4880