User`s guide
Table Of Contents
- Title Page
- Contents
- Getting Started
- Introduction and Measurement
- Phase Noise Basics
- Expanding Your Measurement Experience
- Starting the Measurement Software
- Using the Asset Manager
- Using the Server Hardware Connections to Specify the Source
- Setting GPIB Addresses
- Testing the 8663A Internal/External 10 MHz
- Testing the 8644B Internal/External 10 MHz
- Viewing Markers
- Omitting Spurs
- Displaying the Parameter Summary
- Exporting Measurement Results
- Absolute Measurement Fundamentals
- Absolute Measurement Examples
- Residual Measurement Fundamentals
- What is Residual Noise?
- Assumptions about Residual Phase Noise Measurements
- Calibrating the Measurement
- Measurement Difficulties
- Residual Measurement Examples
- FM Discriminator Fundamentals
- FM Discriminator Measurement Examples
- AM Noise Measurement Fundamentals
- AM Noise Measurement Examples
- Baseband Noise Measurement Examples
- Evaluating Your Measurement Results
- Advanced Software Features
- Reference Graphs and Tables
- Approximate System Noise Floor vs. R Port Signal Level
- Phase Noise Floor and Region of Validity
- Phase Noise Level of Various Agilent Sources
- Increase in Measured Noise as Ref Source Approaches DUT Noise
- Approximate Sensitivity of Delay Line Discriminator
- AM Calibration
- Voltage Controlled Source Tuning Requirements
- Tune Range of VCO for Center Voltage
- Peak Tuning Range Required by Noise Level
- Phase Lock Loop Bandwidth vs. Peak Tuning Range
- Noise Floor Limits Due to Peak Tuning Range
- Tuning Characteristics of Various VCO Source Options
- 8643A Frequency Limits
- 8644B Frequency Limits
- 8664A Frequency Limits
- 8665A Frequency Limits
- 8665B Frequency Limits
- System Specifications
- System Interconnections
- PC Components Installation
- Overview
- Step 1: Uninstall the current version of Agilent Technologies IO libraries
- Step 2: Uninstall all National Instruments products.
- Step 3: Install the National Instruments VXI software.
- Step 4: Install the National Instruments VISA runtime.
- Step 5: Install software for the NI Data Acquisition Software.
- Step 6: Hardware Installation
- Step 7. Finalize National Instruments Software Installation.
- Step 8: System Interconnections
- Step 9: Install Microsoft Visual C++ 2008 Redistributable Package use default settings
- Step 10: Install the Agilent I/O Libraries
- Step 11: Install the E5500 Phase Noise Measurement software.
- Step 12: Asset Configuration
- Step 13: License Key for the Phase Noise Test Set
- Overview
- PC Digitizer Performance Verification
- Preventive Maintenance
- Service, Support, and Safety Information
- Safety and Regulatory Information
- Safety summary
- Equipment Installation
- Environmental conditions
- Before applying power
- Ground the instrument or system
- Fuses and Circuit Breakers
- Maintenance
- Safety symbols and instrument markings
- Regulatory Compliance
- Declaration of Conformity
- Compliance with German noise requirements
- Compliance with Canadian EMC requirements
- Service and Support
- Return Procedure
- Safety and Regulatory Information

266 Agilent E5505A User’s Guide
10
FM Discriminator Measurement Examples
Table 42 Parameter data for the double-sided spur calibration example
Step Parameters Data
1 Type and Range Tab
Measurement Type
•
Start Frequency
•
Stop Frequency
•
Minimum Number of Averages
FFT Quality
Swept Quality
•
Absolute Phase Noise (using an FM
Discriminator)
•
10 Hz
•
100 E + 6 Hz
•
4
•
Normal
•
Fast
2Sources Tab
Carrier Source
•
Frequency
•
Power
•
Carrier Source is Connected to:
Detector Input
•
Frequency
•
1.027 E + 9 Hz
•
19 dBm
•
Test Set
•
1.027 E + 9 Hz
3Cal Tab
FM Discriminator Constant
•
Current Phase Detector
Constant
Know Spur Parameters
•
Offset Frequency
•
Amplitude
Calibration Source
•
Frequency
•
Power
•
Derive Constant from Double-Sided Spur
•
82.25 E-9
•
20 E3
•
-12 dBc
•
1.027 E + 9 Hz
•
16 dBm
4 Block Diagram Tab
•
Carrier Source
•
Phase Shifter
•
DUT in Path
•
Phase Detector
•
Adjust the Quadrature by
adjusting the
•
Manual
•
Manual
•
checked
•
Automatic Detector Selection
•
phase shifter
5 Test Set Tab The test set parameters do not apply to this
measurement example.