Agilent Technologies 6000 Series Oscilloscopes Data Sheet The fastest way to debug your design
The standard for high-performance portable scopes A wide selection lets you choose the 6000 Series model that best matches your needs. The performance and problem solving tools you need to more quickly debug your analog, digital and serial design challenges, in a single instrument. • 100 MHz, 300 MHz, 500 MHz and 1 GHz bandwidths Identify your most elusive problems faster with: Fast update rate View infrequent anomalies that most scopes miss with an update rate 5000 times better than the competition.
Your design has analog, digital and serial signals, shouldn’t your scope? Analog: Up to 1 GHz bandwidth and up to 4 GSa/s sample rate The 6000 Series scope channels provide faster identification of the most elusive problems. • Revolutionary high-resolution display. Engineered with a XGA display and 256 levels of intensity (color grading), see a precise representation of the analog characteristics of the signals you’re testing.
If you haven’t purchased an Agilent oscilloscope lately, why should you consider one now? Leading-edge technology Industry-leading customer support Don’t take our word for it The 6000 Series oscilloscopes incorporate third generation MegaZoom III technology blocks – responsive deep memory, fast update rates with minimal “dead time” and analog-like display systems – and deliver them in a compact package.
Other nice features High resolution mode Offers up to 12 bits of vertical resolution in real-time, single-shot mode. This is accomplished by serially filtering sequential data points and mapping the filtered results to the display when operating at base settings greater than 10-µs/div. AutoProbe interface Automatically sets probe attenuation factors and provides power for selected Infiniium active probes, including the award-winning 1130A 1.5-GHz InfiniiMax differential active probe and 1156A 1.
Why does deep memory matter? See more time This is the most easily understood use of deep memory. The more samples that you acquire, the more time that you can see at a particular sample rate. Long capture times give you better visibility into cause-effect relationships in your design, which greatly simplifies root-cause debugging. It also allows you to capture start-up events (like the start-up sequence below) in a single acquisition.
Why does a fast update rate matter? … improves your chances of finding random events like glitches. And like all other aspects of MegaZoom III technology, this is a real-time acquisition mode. It’s always fast, always on. 100000 10000 1000 100 10 0E -0 5 1. 1. 0E -0 6 1 1. Waveforms per second Reducing the dead time between acquisitions … The Agilent 6000 series fast update rate is truly uncompromised.
Connectivity Our customers tell us that oscilloscope connectivity is an increasingly important feature of their test instruments. That’s why the 6000 Series scopes come with the most comprehensive hardware and software connectivity tools in their class. IntuiLink toolbars Hardware connectivity Scope View logic analyzer and oscilloscope correlation IntuilLink gives you a quick way to move screen shots and data into Microsoft® Word and Excel. These toolbars can be installed from www.agilent.
Probes and accessories Agilent offers a complete family of innovative passive and active probes for the 6000 Series scopes to get your job done easily and accurately. Choosing the correct probe for your application will help to ensure you are acquiring the signals you expect. Probe type Below is a general guide on how to choose the type of probe. For the most up-to-date information about Agilent’s accessories, please visit our web site at www.agilent.com/find/ scope_probes.
Software applications FPGA dynamic probe (N5406A for Xilinx, N5434A for Altera) Give your MSO internal FPGA visibility. Agilent’s MSO FPGA dynamic probe provides internal FPGA visibility and quick instrument setup using an innovative core-assisted debug approach. Measurement tasks that previously took hours can be done in a few mouse clicks. In a few seconds, easily measure a different set of internal signals without changing your FPGA design.
Software applications (continued) CRC error Random errors observed in CAN decode while triggering on data frame ID: 07FHEX. CAN/LIN triggering and decode (N5424A or Option AMS on new scope purchases) Trigger on and decode serially transmitted data based on CAN and LIN protocols. This application not only provides triggering on complex serial signals, but also provides unique hardware-accelerated decode capabilities.
Agilent 6000 Series oscilloscopes: The fastest way to debug your analog, digital and serial designs. MegaZoom III deep memory helps you determine how your signals are impacting each other. With shallow memory scopes, you have to choose whether you look at a slow analog signal or fast digital content. With up to 8 Mpts deep memory, you don’t have to choose – capture all of your data at once.
Built-in storage compartment allows you to store probes and power cord for easy access and transportation. Quickly pan and zoom for analysis with MegaZoom III’s instant response and optimum resolution. QuickMeas shows up to four automated measurements with the push of a button. QuickPrint automatically prints your screen or saves screen images to a connected USB storage device with automated file names.
Accessories Battery power option (Option BAT – factory installed) Agilent 6000 Series oscilloscopes provide an optional internal rechargeable lithium ion battery that will enable 2+ hours without line power. Specifically designed for applications where line power is not available or where you need to take your scope with you but you need more power than a handheld scopemeter provides. New oscilloscopes equipped with this option can also be operated off of the N5429A 12-V automotive adapter.
Product selection guide Looking for a lower cost alternative? Consider the DSO5000 Series. Compare the two popular oscilloscope families in the chart below.
Performance characteristics Acquisition: scope channels Sample rate MSO/DSO601xA/603xA: 2 GSa/sec each channel MSO/DSO605xA/610xA: 4 GSa/sec half channel*, 2 GSa/sec each channel Equivalent-time sample rate: 400 GSa/s (when real-time mode is turned off) Memory depth Standard Optional 2 channels/4 channels 2 Mpts/1 Mpts 8 Mpts/4 Mpts Vertical resolution 8 bits Peak detection MSO/DSO601xA: 1-ns peak detect MSO/DSO603xA: 500-ps peak detect MSO/DSO605xA/610xA: 250-ps peak detect Averaging Selectable f
Performance characteristics (continued) Vertical system: scope channels Scope channels MSO/DSO6xx2A: Ch 1 and 2 simultaneous acquisition MSO/DSO6xx4A: Ch 1, 2, 3 and 4 simultaneous acquisition Bandwidth (–3dB)* MSO/DSO601xA: DC to 100 MHz MSO/DSO603xA: DC to 300 MHz MSO/DSO605xA: DC to 500 MHz MSO/DSO610xA: DC to 1 GHz AC coupled MSO/DSO601xA: 3.5 Hz to 100 MHz MSO/DSO603xA: 3.5 Hz to 300 MHz MSO/DSO605xA: 3.5 Hz to 500 MHz MSO/DSO610xA: 3.5 Hz to 1 GHz Calculated rise time (=0.
Performance characteristics (continued) Vertical system: scope channels (continued) ESD tolerance ±2 kV Noise peak-to-peak MSO/DSO601xA: 3% full scale or 2 mV, whichever is greater MSO/DSO603xA: 3% full scale or 3 mV, whichever is greater MSO/DSO605xA: 3% full scale or 3.6 mV, whichever is greater MSO/DSO610xA: 3% full scale or 4 mV, whichever is greater DC vertical gain accuracy*1 ±2.0% full scale DC vertical offset accuracy ≤200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value; >200 mV/div: ±0.
Performance characteristics (continued) Horizontal Range MSO/DSO601xA: 5 nsec/div to 50 sec/div MSO/DSO603xA: 2 nsec/div to 50 sec/div MSO/DSO605xA: 1 nsec/div to 50 sec/div MSO/DSO610xA: 500 psec/div to 50 sec/div Resolution 2.5 psec Time base accuracy 15 ppm (±0.
Performance characteristics (continued) Trigger system (continued) Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, FlexRay, USB, I2C, SPI, Nth edge burst Selections 20 Edge Trigger on a rising, falling, alternating or either edge of any source Pattern Trigger at the beginning of a pattern of high, low, and don’t care levels and/or a rising or falling edge established across any of the analog and digital channels, but only after a pattern has stabilized for a minimum of 2 nsec.
Performance characteristics (continued) Trigger system (continued) Autoscale Finds and displays all active scope and logic (for MSO6000A series MSO) channels, sets edge trigger mode on highest-numbered channel, sets vertical sensitivity on scope channels and thresholds on logic channels, time base to display ~1.8 periods. Requires minimum voltage >10 mVpp, 0.5% duty cycle and minimum frequency >50 Hz.
Performance characteristics (continued) Display system Display 6.3-inch (161 mm) diagonal color TFT LCD Throughput of scope channels Up to 100,000 waveforms/sec in real-time mode Resolution XGA – 768 vertical by 1024 horizontal points (screen area); 640 vertical by 1000 horizontal points (waveform area) 256 levels of intensity scale Controls Waveform intensity on front panel.
Performance characteristics (continued) Storage Save/recall (non-volatile) 10 setups and traces can be saved and recalled internally. Optional secure environment mode ensures setups and traces are stored to internal volatile memory so data is erased when power is removed. Compliant to NISPOM Chapter 8 requirements. Storage type and format USB 1.
Performance characteristics (continued) General characteristics (continued) Trigger out When Triggers is selected (delay ~17 ns) 0 to 5 V into high impedance 0 to 2.
Ordering information Model Bandwidth Maximum sample rate Memory depth Scope channels DSO6012A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6012A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6014A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6014A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 DSO6032A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 MSO6032A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2 DSO6034A 300 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 4 MSO6034A 300 MHz 2 GSa/s 2
Ordering information (continued) Product upgrades DSO601xA, MSO601xA DSO603xA, MSO603xA 8 Mpts memory upgrade (Factory installed at time of initial scope purchase) DSO605xA, MSO605xA DSO610xA, MSO610xA Option 8ML Option 8MH 8 Mpts memory upgrade (User installed, typically ordered after initial scope purchase) N2911A N2913A DSO to MSO upgrade kit (User installed, typically ordered after initial scope purchase) N2914A* N2915A* Rechargeable battery power option (Factory installed at time of initial sco
Ordering information (continued) Accessories Options Description N2916B Rackmount Kit 1180CZ Testmobile scope cart N2917B Transit case N2919A Testmobile bracket for 1180CZ and 6000 10833A GPIB cable, 1 m long N5916A rackmount kit Related Literature Publication Title Publication Type Publication Number Agilent Technologies Probes and Accessories Selection Guide 5989-6162EN Agilent Technologies 5000 and 6000 Series Oscilloscope Probes and Accessories Data Sheet 5968-8153EN/EUS N5433A an
Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products.