Technical data

150 6000 Series Oscilloscopes Service Guide
6 Replacing 6000L Assemblies
To remove the power supply
1 Perform the previous procedures:
“To remove the bottom cover” on page 145
“To remove the system board” on page 148
2 Disconnect the ground cable and AC cables from the
power supply using a needle nose pliers if necessary.
3 Press the release latch to disconnect the power input
board cable from the power input board.
Figure 53 Removing the power supply.
Power Input
Board Cable
T10 Screws
Power Input
Board
Ground
Connector
Hole in
Divider
AC
Connector
Snap
Fasteners
Power to System
Board
6000_series_service_guide.book Page 150 Friday, March 23, 2007 2:43 PM