Syntax Diagram
Trigger Subsystem Syntax Diagram
TRIG[:IMMediate] Implied Channel-Independent Trigger Command
Description
This implied keyword generates a trigger signal to the electronic load, regardless of which
trigger SOURce is currently in effect. This is the only command that overrides
TRIG:SOUR HOLD. When TRIG:IMM is executed, all pending triggered levels are
transferred to the electronic load’s input. The input also is affected if the transient
generator is enabled in either the PULSe or TOGGle mode. In a multiple electronic load,
a trigger is applied simultaneously to all channels.
Note
When TRIG:IMM is executed in a single electronic load there is brief period (
100
µ
s)
during which the electronic load can also respond to either an external trigger or a <GET>
command. This situation does not occur with multiple electronic loads.
TRIG:IMM affects the WTG bit of the Operation Status Event register (See Chapter 5 -
Status Reporting).
Command Syntax
TRIGger
Parameters
None
Examples
TRIG Immediate trigger commands
TRIG:IMM
Related Commands
None